NORDAC START (SK 135E / SK 175E) – Users Manual for Motor Starters
36
BU 0135 en-4118
2.2.2 Installation of internal customer unit SK CU4-… (installation)
Information
Installation location of customer unit
Installation of the SK CU4-... customer unit
separately
from the device is not permitted. If must always be installed
inside the device in the intended position (option location 1). Only one customer unit can be installed per device!
Prefabricated cables are provided with the customer unit.
Connections are made according to the following table:
Similar to illustration
Bag enclosed with internal customer unit
Allocation of the cable sets (bag enclosed with the customer unit)
Function
Terminal label
Cable colour
Voltage supply (24V DC)
(between device and customer unit)
44
24V
brown
40
GND/0V
blue
Power supply (mains (AC))
(between supply network and customer unit)
L1
L1
brown
L2
L2
black
The customer units are installed inside the housing box of
the device.
The customer unit is fastened with the two screws, which are
provided.
Only one customer unit per device is possible!
Содержание NORDAC START Series
Страница 1: ...BU 0135 en NORDAC START SK 135E SK 175E Users Manual for Motor Starters...
Страница 4: ...NORDAC START SK 135E SK 175E Users Manual for Motor Starters 4 BU 0135 en 4118...
Страница 111: ...8 Additional information BU 0135 en 4118 111 8 1 4 EU Declaration of Conformity...
Страница 119: ...Key word index BU 0135 en 4118 119...
Страница 120: ...6071302 4118...