9. Working with the Editor: Tools menu
NORD MODULAR G2 V1.1
Page 94
F
F
F
F
IIIIL
L
L
LE
E
E
E
B
B
B
B
R
R
R
RO
O
O
OW
W
W
WS
S
S
SE
E
E
ER
R
R
R
This function activates the File Browser floating window. The File Browser
gives a very good overview of all Patches and Performances currently stored
in the internal memory of the connected synth, as well as of Patches and Per-
formances stored on the computer. The Patch and Perf tabs of the File Brows-
er are automatically updated as soon as you perform any of the operations
described below, even if they are done from the synth’s front panel. The File
Browser can be used to save and load Patches and Performances both from
disk and the internal memory of the synth.
There are three tabs in the File Browser window:
D
D
D
D
IIIIS
S
S
SK
K
K
K
Click on the Disk tab to view folders and Patch/Performance files stored on
the computer. Double-click on a folder to step down one level in the hierar-
chy. Click the “arrow up” button to the upper right corner to step up one lev-
el in the hierarchy. Click the refresh (double arrows) button to rescan disks
and/or folders to update the Disk tab contents list.
Load a Patch or Performance to active Slot(s):
Double-click on a Patch or Performance file to automatically load the Patch/Performance to the active
Slot(s) in the synth and open up the Patch/Performance in the Editor Patch window. This is the same as
using File|Open. You can also use the Up and Down arrow keys to select Patch/Performance and load by
pressing Enter.
Load Patch or Performance to Slot or store in internal memory:
By right-clicking on a Patch in the Disk tab you can choose to either load the selected Patch to any of the
Slots of the connected synth and open the Patch in the Editor Patch window, or to save the selected Patch
in an internal memory location. The last function is exactly the same as storing a Patch using the
S
TORE
button and the
R
OTARY
D
IAL
on the Nord Modular G2 front panel (see
).
P
P
P
P
A
A
A
AT
T
T
TC
C
C
CH
H
H
H
Click on the Patch tab to view Patch Banks and Patches stored in the internal memory of the connected
synth.
Load a Patch to active Slot:
Double-click on a Patch to automatically load the Patch to the active Slot in the synthesizer and open up
the Patch in the Editor Patch window. This function is exactly the same as loading a Patch using the
P
ATCH
L
OAD
button and the
R
OTARY
D
IAL
on the Nord Modular G2 front panel (see
). You can also use the Up and Down arrow keys to select Patch and load by
pressing Enter. You can also open and close the content of an entire Bank by clicking the Bank icon or
selecting it (with the arrow keys or the mouse) and pressing Enter.
Store or delete Patch from internal memory:
By right-clicking on a Patch in the Patch tab you can choose to either store the Patch of the active Slot
in the selected memory location, or to delete the selected Patch from its memory location, or change Sort
Mode.