5 Service and maintenance
B 1050 en-3921
77
5.2.4 Cleaning the heat exchanger (Option: CS2-X)
Clean the heat exchanger of the oil/air cooler (Option: CS2-X) regularly in order to maintain the
efficiency. Pay attention to the operating instructions of the oil/air cooler.
5.2.5 Oil level
The installation position must comply with the version on the name plate.
WARNING
Risk of burns and injuries
• Switch off the drive before checking the oil level.
• Secure the drive against inadvertent switching on, for example with a padlock.
• Allow the gear unit to cool down. The oil temperature should be between 20 °C and 40 °C.
Checking the oil level
Information
The SAFOMI option requires a different procedure for checking and adjusting the oil level than that
which is described here (see chapter 5.2.5.6 "No-seal adapter for agitators (Option: SAFOMI)").
1. Shut down the drive.
2. Make sure to wait for 5 to 10 minutes.
3. Check the oil level only if the gear unit is at a standstill and if the oil is free from foaming.
– An oil level above the “Max” marking is impermissible and may indicate the ingress of foreign
liquids (e.g. water).
Check the water content of the oil.
– An oil level below the “Min” marking is impermissible and may indicate a leak.
An impermissible oil level may damage the gear unit.
– Find and correct the reason for the incorrect oil level.
– If applicable, correct the oil level or change the oil (see section 5.2.10 "Oil change").
Use the gear oil type stated on the type plate.
– If possible, filling should be carried out via the vent position.
Other filling positions are possible. The specific dimension sheet for the order is definitive.
For the positions of the oil level measuring device, the vent and the oil drain, please refer to the
specific dimension sheet for the order.
For double gear units (Option: WG) and gear units with auxiliary drive (Option: WX) the oil level must
be checked on both gear units. For auxiliary drives with freewheeling couplings the oil level in the
attachment cylinder must also be checked.
Oil level checks and top-ups may be necessary for attached couplings. In this case, the
manufacturer's documentation must be observed.
Содержание 6052902/0213
Страница 1: ...B 1050 en Industrial gear units Manual with installation instructions...
Страница 2: ...Industrial gear units Manual with installation instructions 2 B 1050 en 3921...
Страница 7: ...Publisher B 1050 en 3921 7...
Страница 17: ...2 Description of gear units B 1050 en 3921 17 Figure 1 MAXXDRIVE XT 2 stage helical bevel gear unit...
Страница 97: ...7 Appendix B 1050 en 3921 97 Gear units SK 5207 SK 10507 M1 oil screw holes...
Страница 99: ...7 Appendix B 1050 en 3921 99 Gear units SK 5207 SK 10507 M3 oil screw holes...
Страница 101: ...7 Appendix B 1050 en 3921 101 Gear units SK 5207 SK 10507 M5 oil screw holes...
Страница 103: ...7 Appendix B 1050 en 3921 103 Gear units SK 11207 SK 15507 M1 oil screw holes...
Страница 105: ...7 Appendix B 1050 en 3921 105 Gear units SK 11207 SK 15507 M3 oil screw holes...
Страница 107: ...7 Appendix B 1050 en 3921 107 Gear units SK 11207 SK 15507 M5 oil screw holes...
Страница 109: ...7 Appendix B 1050 en 3921 109 Gear units SK 5217 SK 11217 M1 oil screw holes...
Страница 111: ...7 Appendix B 1050 en 3921 111 Gear units SK 5217 SK 11217 M5 oil screw holes...
Страница 126: ...Industrial gear units Manual with installation instructions 126 B 1050 en 3921...
Страница 127: ...Key word index B 1050 en 3921 127...
Страница 128: ...6052902 3921...