8 Additional information
BU 0600 en-3221
243
I
Setpoint source and
setpoint selection
II
Signal processing
and ramp
III
Control and motor
model (determination
of slip)
8.9 Definition of setpoint and actual value processing (frequencies)
The frequencies used in parameters (P502) and (P543) are processed in various ways according the
following table.
Function
Name
Meaning
Output to ...
without
Right/
Left
with
Slip
I
II
III
8
Setpoint frequency
Setpoint frequency from
setpoint source
X
1
Actual frequency
Setpoint frequency for motor
model
X
23
Actual frequency
with slip
Actual frequency at motor
X
X
19
Setpoint frequency
master value
Setpoint
frequency from
setpoint source
Master value
(free from enable correction)
X
X
20
Setpoint frequency
n R master value
Setpoint frequency for motor
model
Master value
(free from enable correction)
X
X
24
Master value of
actual frequency
with slip
Actual frequency at
motorMaster value
(free from enable correction)
X
X
X
21
Actual frequency
without slip master
value
Actual frequency without
master value slip
Master value
X
Table 17: Processing of setpoints and actual values in the frequency inverter
Содержание SK 510P
Страница 1: ...BU 0600 en NORDAC PRO SK 500P Manual with installation instructions...
Страница 4: ...NORDAC PRO SK 500P Manual with installation instructions 4 BU 0600 en 3221...
Страница 223: ...7 Technical data BU 0600 en 3221 223...
Страница 233: ...8 Additional information BU 0600 en 3221 233 8 3 4 EU Declaration of Conformity...
Страница 253: ...Key word index BU 0600 en 3221 253...
Страница 254: ...NORDAC PRO SK 500P Manual with installation instructions 254 BU 0600 en 3221...
Страница 255: ...Key word index BU 0600 en 3221 255...
Страница 256: ...6076002 3221...