NORD USS and Modbus RTU Manual
54
Subject to technical amendments
BU 0050 GB-3111
Parameter
Setting value / Description / Note
Comments
P543 (P)
Bus
– Actual value 1
(Bus
– Actual value 1)
0 ... 12 (24)
{ 1 }
The return value 1 (IW1) can be set for bus control in this parameter.
SK 300E, SK 700E SK 750E
0 =
Off
1 =
Actual frequency
2 =
Actual speed
3 =
Current
4 =
Torque current
5 =
Status of digital inputs and relay
6 =
Actual position (only
POSICON,
SK700/750E
)
7 =
Setpoint position (only
POSICON,
SK700/750E
)
8 =
Setpoint frequency
9 =
Error number
10 =
Actual position increment
1
(only
POSICON, SK700/750E
)
11 =
Setpoint position increment
1
(only
POSICON, SK700/750E
)
12 =
BUS I/O Out Bits 0-7
SK 500E
0 =
Off
1 =
Actual frequency
2 =
Actual speed
3 =
Current
4 =
Torque current (100% = P112)
5 =
State of digital inputs and outputs
2
6 =
Actual position Low word
7 =
Setpoint position Low word
8 =
Setpoint frequency
9 =
Error number
10 =
Actual position increment Low word
11 =
Setpoint position increment Low word
12 =
Bus I/O Out Bits 0...7
13 =
Actual position High word
14 =
Setpoint position High word
15 =
Actual position increment High word
16 =
Setpoint position increment High word
17 =
Value analog input 1 (P400)
18 =
Value analog input 2 (P405)
19 =
Setpoint frequency master value (P503)
20 =
Setpoint frequency after master value ramp
21 =
Actual frequency without master value slip
22 =
Speed from encoder
(only possible with SK 52x/53xE and
encoder feedback)
23 =
Actual frequency with slip,
"Actual frequency
with slip"
24 =
Master value, actual freq. with slip,
"Master
value, actual freq. with slip"
NOTE:
For
SK 540 and SK545E
5 actual values are available. These are all set in
parameter P543, which is divided into 5 array elements for this purpose.
Parameters P544 and P545 are not required for this inverter version.
[-01] =
Actual bus value 1
[-02] =
Actual bus value 2
[-03] =
Actual bus value 3
[-04] =
Actual bus value 4
[-05] =
Actual bus value 5
P544 (P)
Actual bus value 2
(Actual bus value 2)
except SK 54xE
0 ... 12 (24)
{ 0 }
The return value 2 (IW2) can be set for bus control in this parameter.
For setting values, see parameter (P543)
P545 (P)
Actual bus value 3
(Actual bus value 3)
except SK 54xE
0 ... 12 (24)
{ 0 }
In this parameter, the return value 3 (IW3) can be set for bus control. This is only available if P546
3 (only applies for SK 700E / SK 750E).
For setting values, see parameter (P543)
1
An indicated revolution of the motor results from 8192 encoder increments.
2
The assignment of the digital inputs in P543/ 544/ 545 = 5
Bit 0 = DigIn 1
Bit 1 = DigIn 2
Bit 2 = DigIn 3
Bit 3 = DigIn 4
Bit 4 = DigIn 5
Bit 5 = DigIn 6
Bit 6 = DigIn 7
Bit 7 = Reserved
Bit 8 = Reserved
Bit 9 = Reserved
Bit 10 = Reserved
Bit 11 = Reserved
Bit 12 = Out 1
Bit 13 = Out 2
Bit 14 = Out 3
Bit 15 = Out 4