2 Mounting and installation
BU 0240 en-US-4920
25
Pos: 77 /Anl eitungen/Elektronik/FU und Starter/2. M ontage und Install ati on/M ontage/M otormontage - Standard [SK 1xxE, SK 2xxE]/Arbeitsgänge für di e M otorm ontag e [SK 2xxE] @ 1\mod_1341488911979_14638.docx @ 29976 @ 3 @ 1
2.1.2 Motor installation steps
1. If necessary, remove the original terminal box from the NORD motor so that only the base of the terminal
box and the motor terminal block remain.
2. Place the bridges for the correct motor circuit on the motor terminal block and connect the ready-made
cables for motor and PTC thermistor connections to the respective connection points on the motor.
3. Mount the connection unit on the terminal box base of the NORD motor using the existing screws and
gasket as well as the enclosed toothed/contact washers. When doing this, align the housing so that the
rounded side is facing in the direction of the A end shield of the motor. Carry out mechanical adaptation
using the adapter kit (
2.1.2.1 "Adapters for motor size"). In general, check whether motors made by
other manufacturers can be connected.
Figure 2: Connection unit size 1 … 3
Figure 3: Connection unit size 4
4. Fasten insulating plate above the motor terminal block.
– Size 4: Fasten toroidal core to insulating plate (
Section 2.1.1 "Installation of insulating plate – size
4").
Screw on power terminal block above this using 2x M4x8 screws and the plastic washers (size 4: 3x M4 cap
nuts).
5. Make electrical connections. Use screwed connections appropriate for cable cross-section for the cable
entry of the connecting cable.
6. Place the variable frequency drive on the connection unit. When it
comes to sizes 1 to 3, pay special attention to the correct contacting of
the PE pins. These are located diagonally in 2 corners of the variable
frequency drive and the connection unit.
In order to ensure that the degree of protection for which the device is
intended is achieved, make sure that all fastening screws that attach
the variable frequency drive to the connection unit are tightened
crosswise, step by step and at the torques indicated in the table below.
The cable screw connections used at a minimum must correspond to
the degree of protection of the device.
Size SK 2xxE
Screw size
Tightening torque
Size 1
M5 x 45
2.0 Nm ± 20%
Size 2
M5 x 45
2.0 Nm ± 20%
Size 3
M5 x 45
2.0 Nm ± 20%
Size 4
M6 x 20
2.5 Nm ± 20%
Pos: 78 /Allgem ein/Allgem eing ültige M odul e/---------Seitenum bruch kom pakt --------- @ 13\mod_1476369695906_0.docx @ 2265496 @ @ 1
Содержание NORDAC FLEX SK 205E Series
Страница 1: ...BU 0240 en US NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters...
Страница 4: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 4 BU 0240 en US 4920...
Страница 29: ...2 Mounting and installation BU 0240 en US 4920 29 Installation Size 1 3 Size 4...
Страница 97: ...Key word index BU 0240 en US 4920 97...
Страница 98: ...NORDAC FLEX SK 200E SK 235E Brief instructions for Frequency Inverters 98 BU 0240 en US 4920...
Страница 99: ...Key word index BU 0240 en US 4920 99...
Страница 100: ...6072403 4920...