5. Repair Flow Chart
Panel Control Circuit
No Display
Replace panel or
FPC cable to panel
Replace Q401, Q400
Check U403 crystal
X400 (14.318MHZ)
Replace X400
Check power supply for
1.8V, 2.5V, and 3.3V
Check relative circuit
Replace U403
OK
OK
OK
OK
NO 5V
NO Signal
NG
NG
Check CN605 pin 19-22
is 5V and signal on pin
3,4,6,7,9,10,12,13,15,16
Check Q401, Q400
relative circuit