background image

 

 

Hold Time 

 

Active  

From 

 

Zero Torque 

 

 

Torque display 

 

Torque input 

 

Auto Reset 

Trigger 

Peak Reading with Auto Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When Torque is applied, the NorTronic

®

 will track the torque input until it has exceeded the 

Active From

 

setting

 

(See page 19) and then enters into peak mode for both Torque & Angle. 

 

The angle display is shown as “

0

°

” until the torque is above the 

Active

 

From

 

setting for the tool. If the 

Snug

 

Torque

 is set, the angle display is shown as “

0

°

” until the torque reaches the 

Snug

 

Torque

 value (see page 

13) and then displays the angle value in peak mode. 

 

When a peak torque or angle has been applied after which the torque has dropped below the 

Active

 

From

 

setting, both the torque & angle readings continuously flash for the duration of the 

Hold

 

Time

 (see page 21). 

The displays are then reset to the current torque input.

 

 

If the 

Save

 

button (which now becomes

 

latching

) has been pressed prior to the 

Peak

 being 

detected, the 

Torque

 

&

 

Angle

 readings are 

saved

 

to the

 

Data

 

Store

 on the NorTronic

®

 

If a

 

Target

 

is in use, press the UP button to

 

delete

 

the

 

last

 

reading

 

that has been

 

saved 

via 

 

the

 

Delete Last Result?

 

confirmation screen

 

 

Delete 

Last Result ?

 

 

Y / N

 

 

Tool Target 

 

Having already set a 

Tool

 

Target

 (see page 13 for more details), the NorTronic

®

 beeps as the applied torque 

approaches the Torque Target (starting slow and getting faster) until a continuous tone is heard when the 

Target has been reached. This stops after the Torque has been released. 

 

The Torque & Angle digits will be shown as: 

White = below Active From setting or no Target set 
Yellow = above Active From setting, but below Target Lower Limit 
Green = above Target Lower Limit and below Target Upper Limit 
Red = above Target Upper Limit 

 

The tool 

Vibrates

 when the 

Torque

 

Target

 or 

Angle Target

 has been reached (if enabled in 

SETUP

 

 

Vibrate

, see page 20 for more information). 

 

TIP:  If an angle only target has been set, the beeper sounds as the user approaches the angle 

target, quickening in frequency until a continuous tone when the angle target has been 

reached.

 

Содержание NorTronic 43500

Страница 1: ...ORBAR TORQUE TOOLS NZ LTD B3 269A Mt Smart Road Onehunga Auckland 1061 NEW ZEALAND Tel 64 9579 8653 Email nz norbar com au NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371 Email singapore norbar com au NORBAR TORQUE TOOLS SHANGHAI LTD E Building 5F no 1618 Yishan Road Minhang District Shanghai CHINA 201103 Tel 86 21 6145 0368 Email sales norb...

Страница 2: ......

Страница 3: ...get 8 Torque Units Change 9 Zero Display Offset 9 Reading 9 Sleep 9 Resume from Sleep Gyroscope drift calibration 9 USB Interface 10 Wireless Interface 11 Low Battery 11 Flat Battery 11 Exit Measure Display Options Menu 11 TDS Receive Results Interface 12 Tool Target SETTING 13 Set Target Units 13 Set Snug Torque 13 Set Angle Target 13 Set Torque Target 13 Linked Targets 14 TDS Target Interface 15...

Страница 4: ...ew Results 22 Erase All 22 About 23 Specifications 24 Maintenance 25 NorTronic Calibration 25 Battery Replacement 25 Repair 25 Cleaning 25 Product Disposal 25 Battery Disposal 25 Trouble Shooting 26 Glossary of Terms 26 ...

Страница 5: ...by This Manual Part Number Torque Capacity Ratchet Square Drive Wireless Communication Frequency 43500 50 N m 868 MHz 43501 50 N m 868 MHz 43502 200 N m 868 MHz 43503 330 N m 868 MHz 43504 50 N m 915 MHz 43505 50 N m 915 MHz 43506 200 N m 915 MHz 43507 330 N m 915 MHz Parts Included Parts Included Part Number Quantity NorTronic electronic torque wrench 4350X 1 USB flash drive Manuals Software 6113...

Страница 6: ...urement against Target status Audible indication of Target status Vibration feedback when Target reached 4 digit resolution for all NorTronic electronic torque wrenches Maximum of 3000 date time stamped reading memory store 5 user buttons Operational from three AA internal rechargeable non rechargeable batteries Ability to link targets for applications that require tightening in a sequence via TDS...

Страница 7: ...TCHING ON WIPE OFF ANY MOISTURE BEFORE USE Battery Fitting Replacement NOTE Insert positive battery terminal into handle cavity first Rotate the end cap clockwise to tighten and counter clockwise to release Ratchet Head Fitting Replacement NOTE All NorTronic tools are Torque Handles with a 16mm spigot Should you wish to change to a different spanner end fitting depress the plunger on the ratchet h...

Страница 8: ...ed to P C TDS 5 Low Battery Flat Battery 6 Current Torque Units 7 Torque reading 8 Angle reading 9 Current Snug Torque Angle Target 10 Torque CRS has been changed from default value Button Function Operation SETUP Change Units Scroll through options or change a selected value When changing a value hold the button down for a faster rate of change Zero Torque Angle display if below the Active From t...

Страница 9: ...shown as 0 until the Torque is above the Active From setting for the tool If the Snug Torque value is set See page 13 and is above the Active From setting the Angle display is shown as 0 until the Torque reaches the Snug Torque value and then displays the Angle value in peak mode After a Peak Torque or Angle has been applied and then the Torque has dropped below the Active From setting both the To...

Страница 10: ...ing detected the Torque Angle readings are saved to the Data Store on the NorTronic If a Target is in use press the UP button to delete the last reading that has been saved via the Delete Last Result confirmation screen Delete Last Result Y N Tool Target Having already set a Tool Target see page 13 for more details the NorTronic beeps as the applied torque approaches the Torque Target starting slo...

Страница 11: ... NorTronic memory the Reading bottom left of display is incremented This is reset when the Tool Target has been changed Sleep The NorTronic will Sleep if any of the events listed below have not happened during the time period specified in Tool SETUP Sleep see page 19 for more information a A button has been pressed b The Torque reading has changed by more than 2 of the wrenches capacity TIP The No...

Страница 12: ...erface The NorTronic can be connected to a PC with TDS installed using the cable supplied NOTE Remove the USB cover to access the USB connector The USB cover must be fitted for IP44 protection Test Results saved on the NorTronic to the Data Store will be copied to TDS when synchronising The Tool Target and Tool SETUP configuration can also be sent from TDS When connected the USB icon will appear o...

Страница 13: ...attery The LOW BATTERY icon will be shown when there is approximately 20 minutes of operational life left in the NorTronic NOTE This icon will overwrite the Wireless or USB icons but the NorTronic will remain connected Flat Battery The Flat Battery icon will be shown for approximately 30 seconds before shutting down Further button presses will not wake up the tool The batteries must be removed and...

Страница 14: ...ll change from to when the tool is connected to Receive Results in TDS After a peak has been detected press ZERO to send both the peak Torque Angle values to Receive Results in TDS If the tool is configured for Auto Reset the readings are automatically sent during the Hold Time The save button is inactive i e Test Results are NOT saved on the NorTronic When the button is pressed Test Results will ...

Страница 15: ... the Set Angle Target The button is not functional Minimum 0 Maximum 100 of NorTronic Torque capacity Set Angle Target NOTE This screen will not be shown if Angle is Not Enabled in SETUP Set Angle 32 Press or to change Press to confirm and go to Set Torque Target The button is not functional Minimum 0 Maximum 999 Set Torque Target Set Target N m 298 4 Press or to change Press to confirm and go to ...

Страница 16: ...e specified in the TDS Target Linked Targets can be sent via the USB or Wireless interface to the Tool If after the final Target has completed and No further Target has been specified the Target becomes not enabled i e No Target is shown on the Tool To carry on link the last Target to the first ...

Страница 17: ... can be changed on the tool unless the Locked option has been ticked in Set Tool Options and downloaded to the NorTronic by clicking the Update button on Set Tool Options as shown below See page 16 for more information on Set Tool Options The Locked option disables the NorTronic user from altering the Target SETTING and Tool SETUP on the NorTronic ...

Страница 18: ...udes Limits Units Time Date Sleep Angle Display Auto Zero Active From Vibrate Wireless Auto Reset Display and Torque Centres NOTE Tool SETUP is active unless the Lock option has been ticked and downloaded to NorTronic via the TDS software This disables the NorTronic user from altering the Tool SETUP or Target SETTING ...

Страница 19: ...nge highlighted value Press to confirm and go to LO Limit Press to exit to SETUP saving changes of Torque Target setting Minimum 0 Maximum 20 Default 4 Angle Limits Angle HI Limit 4 LO Limit 4 Press or to change highlighted value Press to confirm and go to LO Limit Press to exit to SETUP saving changes Target HI Limit Target LO Limit in degrees Minimum 0 Maximum 20 Default 4 NOTE Tool SETUP is a s...

Страница 20: ... or to highlight unit Press to enable green or disable red Press to confirm and exit to SETUP saving changes Minimum Enabled 1 Maximum Enabled All 12 Default All 12 Date Time Date Time 24 01 14 16 05 14 Press or to change highlighted value Press or to confirm and step onto next change month year hours minutes seconds 24 hour clock format The Time Date will always be checked and updated when synchr...

Страница 21: ...to change setting Press or to confirm and exit to SETUP Enabled Display Torque Angle Not Enabled Display Torque only Auto Zero Auto Zero Enabled Press or to change setting Press or to confirm and exit to SETUP Enabled both the TORQUE ANGLE readings will Auto Zero on power up or resume from sleep Not Enabled the user must press the ZERO button to reset the Torque display to the current Torque input...

Страница 22: ... Enabled Wireless communication is Not Active Wireless Enabled Node 2 868 MHz Press or to change value Press to confirm and go to 868 915 MHz Press to confirm and exit to SETUP saving changes A Node number is an individual identification of a tool on the wireless network If multiple NorTronic tools are communicating with the same USB wireless adapter at the same time they must each have individual...

Страница 23: ... 0 Hold Time Hold Time 4Sec Press or to change value Press or to confirm and go to SETUP saving changes Minimum 1 Maximum 10 Default 4 Display Inverse Not Enabled Press or to change value Press or to confirm and go to SETUP saving changes Enabled Black digits on White background Not Enabled White digits on Black background when in the Measure display WARNING WHITE DIGITS ON BLACK BACKGROUND WILL R...

Страница 24: ...334 6 N m 93 Press the or buttons to scroll through the Saved Test Results screen s Press the button on to exit back to Data Store Result 30 03 12 10 48 23 360 5 N m 101 Erase All Delete Results Y N Press or to change highlighted option Press to confirm Press to go to SETUP WARNING SAVED TEST RESULTS CANNOT BE RETRIEVED FROM THE TOOL ONCE THEY HAVE BEEN DELETED ...

Страница 25: ...ch of the 3 screens starting with serial is displayed for 2 seconds before returning to SETUP Tool Identification SERIAL 2012 123456 MODEL 4350X Version Version 1 XX Hardware options fitted Options Wireless Angle ...

Страница 26: ...t NiMH Nickel metal Hydride Coin cell Renata 36 mAh CR1220 Materials finish Handle Powder coated aluminium Body tube Xylan coated steel Lever arm Nickel plated steel Ratchet head Chrome plated steel Battery cap polished stainless steel Environmental protection IP44 Electromagnetic Compatibility In conformance with EN 61326 2006 EMC Directive USB 2 0 Device 5 pin mini Wireless Transceiver 868 MHz c...

Страница 27: ...bar or by a Norbar approved agent where all the facilities to ensure the NorTronic is functioning at maximum accuracy are available Cleaning Do not use abrasives or solvent based cleaners Product Disposal This symbol on the product indicates that it must not be disposed of in the general waste Please dispose of according to your local recycling laws and regulations Contact your distributor or see ...

Страница 28: ...e Frequency of beep does not get faster when approaching a Target Apply the torque slower GLOSSARY OF TERMS Word or Term Meaning Number Active From Value from which the memory modes operate Capacity NorTronic full scale CRS Centres Frequency Response Frequency value below which signals are passed Hold Time The length of time a reading is displayed until automatically reset Hz Hertz unit of frequen...

Отзывы: