Страница 1: ...User Guide 7077 000 02 Cover indd 1 11 18 2009 2 27 52 PM...

Страница 2: ...Your Finger 10 Activating the Device and Verifying Operation 12 Reading Your Results 13 Care and Maintenance 15 Specifications 20 Equipment Response Time 23 Testing Summary 24 SpO2 Accuracy Testing 24...

Страница 3: ...nts of Package GO2 Achieve One AAA Alkaline Battery User Guide Quick Guide Symbols The following symbols are associated with your GO2 Achieve Symbol Definition of Symbol Consult Instructions for Use C...

Страница 4: ...ended Use GO2 Achieve is intended to measure blood oxygen saturation SpO2 the amount of oxygen in your blood and pulse rate of both adults and children It is designed for fingers not the thumb between...

Страница 5: ...ficial nails and any tests recently performed on you that required an injection of intravascular dyes The GO2 Achieve may not work if you have poor circulation Rub your finger to increase circulation...

Страница 6: ...s for the GO2 Achieve and its components including the battery The GO2 Achieve is a precision electronic instrument and must be repaired by Nonin Technical Service Installing the Battery One 1 5 volt...

Страница 7: ...low battery as soon as possible Applying the GO2 Achieve to Your Finger Hold the GO2 Achieve with the display facing toward you slide your finger into the opening at the bottom of the device as shown...

Страница 8: ...ings Activating the Device and Verifying Operation The GO2 Achieve automatically turns on when a finger is inserted When a finger is inserted the GO2 Achieve performs a brief self test as shown below...

Страница 9: ...o another finger While the GO2 Achieve is calculating its reading immediately after activating the device the sensor disconnect indicator will appear The sensor disconnect indicator also appears when...

Страница 10: ...once per week or more frequently if handled by multiple users Caution Do not place the GO2 Achieve in liquid or clean it with agents containing ammonium chloride isopropyl alcohol or products that ar...

Страница 11: ...o cold Allow device to sit at room temperature for at least 30 minutes If the problem persists contact Nonin Technical Service Troubleshooting Missing segments on LCD display No readings Faulty displa...

Страница 12: ...Wavelengths and Output Power Red 660 nanometers 0 8mW Max Average Infrared 910 nanometers 1 2mW Max Average 1 Arms represents approximately 68 of measurements Parts and Accessories GO2CC Black neopren...

Страница 13: ...e of Protection Type BF Applied Part Enclosure Degree of Ingress Protection IP33 Mode of Operation Continuous This equipment complies with International Standard IEC 60601 1 2 2004 for electromagnetic...

Страница 14: ...ipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use Pulse Rate Motion Testing This test measures pulse rate oximeter accuracy with...

Страница 15: ...ithin specifications GO2 Achieve is a precision electronic instrument and must be repaired by Nonin Technical Service Any sign or evidence of opening the GO2 Achieve field service by non Nonin personn...

Страница 16: ...s number if you have to contact Nonin with technical service issues or if you have any questions regarding the use or performance of your pulse oximeter Nonin s technical service department can be rea...

Страница 17: ...www go2nonin com 70 C 30 C 0123 GO 2 SpO 2 G O 2 SpO 2 2 Warning Keep away from small children this device contains small parts that may pose a choking hazard 7077 000 02 Cover indd 2 11 18 2009 2 27...