![Nokia RM-57 Скачать руководство пользователя страница 241](http://html.mh-extra.com/html/nokia/rm-57/rm-57_service-manual_1699439241.webp)
Nokia Customer Care
Appendix A: RF Troubleshooting
Company Confidential
Copyright
©
2005 Nokia. All rights reserved
A-23
3.1.1.1.1.1 Ferrite inductor L7503 ok?
•
Check that component is in place and solder joints are ok
•
Measure voltage from the both ends of L7503. Is it faulty or is there short circuit in RF end?
•
Disconnect the power supply from the phone and use an ohmmeter to check that inductor is
conducting DC.
3.1.1.1.2 RFBUS signals ok?
•
GSM receiver has to be active before RFBUS signals can be measured. Procedure is explained
in section “GSM RX chain activation for manual measurements”. Also WCDMA/GSM transmitter
and WCDMA receiver activation can be used for the measurement but then RFBUS -signals
don’t necessarily look like in figures mentioned below.
•
Measurements can be performed with an oscilloscope and a probe. Check all five RF BUS
signals:
-
RFBUSDAT
: Connect the probe to J7504. Typical RFBUSDAT -signal is shown in section 6.5.9.3
”
-
RFBUSCLK
: Connect the probe to J7505. Typical RFBUSCLK -signal is shown in sections 6.5.9.1
” and 6.5.9.2 “
RFBUSCLK and RFBUSENA (GSM RX)
-
RFBUSENA
: Connect the probe to J7506. Typical RFBUSENA -signal is shown in section 6.5.9.2
RFBUSCLK and RFBUSENA (GSM RX)
”
-
RXRESETX
: Connect the probe to J7515. RXRESETX -signal is a constant 2 V DC-signal after GSM
transceiver has been activated the first time after phone boot up. The level of this signal
should be about 0 V before transceiver activation.
-
TXRESETX
: Connect the probe to J7517. TXRESETX -signal is a constant 2 V DC-signal after GSM
transceiver has been activated the first time after phone boot up. The level of this signal
should be about 0 V before transceiver activation.
3.1.1.1.2.1 RAP3G (or Vinku or Hinku) faulty?
•
RAP3G (D2800) cannot be replaced.
3.1.1.1.3 Vinku (N7501) regulator voltages VREG1, VREG2 ok?
•
GSM transmitter has to be active before VREG1 and VREG2 voltages can be measured.
Procedure is explained in section “Transmitter troubleshooting.”
•
Measurements can be done with an oscilloscope and a probe.
•
VREG1: Connect the probe to C7543
•
VREG2: Connect the probe to C7548 (or C7547)
Содержание RM-57
Страница 327: ...9 System Module Nokia Customer Care Issue 1 Company Confidential Page 9 1 Copyright 2005 Nokia All Rights Reserved ...
Страница 377: ...10 Schematics Nokia Customer Care Issue 1 Company Confidential Page 10 1 Copyright 2005 Nokia All Rights Reserved ...
Страница 391: ...www s manuals com ...