![Nokia RH-29 Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/nokia/rh-29-series/rh-29-series_manual_1699380018.webp)
RH-29
Company Confidential
6b - RF Troubleshooting
Nokia Customer Care
Page 14
Copyright
©
2004 Nokia Corporation
Issue 1 05/2004
Company Confidential
Receiver troubleshooting
Set up Phoenix as if doing RSSI measurements.
Ascertain which Rx band is faulty.
Refer to Rx troubleshooting flowchart.
Set signal generator frequency to 942.46771MHz for EGSM900 or 1847.86771MHz for
DCS1800.
Set signal generator amplitude to -60dBm.
Select Receive Band
For Testing.
Probe J606-609 for RX I & Q
Does Waveform
look like example?
Check RSSI using Phoenix.
Does it match Sig. Gen Output level?
Receiver is working
correctly.
Probe J211 &
J212. Is digital
data visible?
Replace UEM
Replace UPP
Check SAW
Output / Mjoelner
Input for band. OK?
Check Mjoelner
Voltage Supplies &
RFBUS lines.
All OK?
Refer to BB
Fault Finding
Replace
Mjoelner
Check Antenna
Switch Test Point.
Signal OK?
Check PI Filter & SAW
Components. OK?
Replace all 3
Components
Replace
SAW Filter
Check Antenna
Switch Cont.
lines. Do they
match the results
in the table?
Replace
Antenna
Switch
Check
L701, L702
L703. OK?
Replace
Inductor
YES
NO
YES
NO
YES
NO
YES
YES
NO
NO
YES
NO
YES
NO
YES
NO
NO
YES
Test With
Oscilloscope
Test With
Spectrum Analyzer
End
Action
KEY
Measure Vge at
same point. 0.2V?
Inspect PI filter &
SAW for S/c. S/C?
Rectify S/C
YES
NO
YES
NO
Inspect RF
Connector.
OK?
Replace RF
Connector
YES
NO
Inspect /
Check
Is LO Running?
Refer to Synth.
Flow Chart.
NO
YES
YES
C650.
C650.
.
Probe J200 and J202, is
digital data visible?
OK?
Replace
UEM.