CCS Technical Documentation
Troubleshooting - Baseband
RH-27
Issue 1 11/2003 Confidential
©
2003
Nokia Corporation
Page 11
A charge pump used by VR1A is constructed around UEM. The charge pump works with
Cbus (1.2 MHz Clk) and gives a 4.75 V regulated output voltage to RF.
Clock Distribution
RFClk (19.2 MHz Analog)
The main clock signal for the baseband is generated from the voltage and temperature
controlled crystal oscillator VCTCXO (G503). This 19.2 MHz clock signal is generated at
the RF and fed to RFCLK pin of UPP.
Table 1: RH-27 Baseband Regulators
Regulator
Maximum
current
(mA)
Vout (V)
Notes
VCORE
DD/DC
300
1.5
Output voltage selectable 1.0V/1.3V/1.5V/1.8V
Default power at power-up is 1.5V
VIO
150
1.8
Enabled always except during power-off mode
VFLASH1
70
2.78
Enabled always except during power-off mode
VFLASH2
40
2.78
Enabled only when data cable is connected
VANA
80
2.78
Enabled only when the system is awake (off during sleep and
power-off modes)
VSIM
25
3.0
Not used on Columbia platform
Table 2: RH-27 RF Regulators
Regulator
Maximum
current
(mA)
Vout (V)
Notes
VR1A
10
4.75
Enabled when the receiver is on
VR1B
10
4.75
Enabled when the transmitter is on
VR2
100
2.78
Enabled when the transmitter is on
VR3
20
2.78
Enabled when SleepX is high
VR4
50
2.78
Enabled when the receiver is on
VR5
50
2.78
Enabled when the receiver is on
VR6
50
2.78
Enabled when the transmitter is on
VR7
45
2.78
Enabled when the receiver is on