AT+IFC DTE-DCE Local Flow Control
This command is used to control the operation of local flow control
between the DTE and the data adapter. <DCE_by_DTE> specifies the
flow control used by DTE to control the flow of received data from
the data adapter. <DTE_by_DCE> specifies the flow control used by
a data adapter to control the flow of transmitted data from the DTE.
Syntax:
AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>
Set flow control.
AT+IFC? Query
current
setting.
Response is
+IFC:<DCE_by_DTE><DTE_by_DCE>.
AT+IFC=?
Show valid range of parame-
ters.
Response is +IFC:(0-3),(0-2).
Parameters:
<DCE_by_DTE>
0
no flow control
1
XON/XOFF (software) flow control
2
CTS/RTS (hardware) flow control
3
both XON/XOFF and CTS/RTS flow control
<DTE_by_DCE>
0
no flow control
1
XON/XOFF (software) flow control
2
CTS/RTS (hardware) flow control
AT+IPR Fixed DTE Rate
This command specifies the data rate at which the data adapter will
accept commands.