![Nokia NPL-4 Series Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/nokia/npl-4-series/npl-4-series_troubleshooting-instructions_1699328019.webp)
Nokia Customer Care
Troubleshooting Instructions
Company confidential
NPL-4/5/
Issue 2 05/05
Copyright
© 2005
Nokia Corporation. All rights reserved.
Page 19
Figure 9: Signal Measurement
- Choose the remaining GSM bands and measure accordingly the procedure described
above.
Measuring front-end power levels using spectrum analyzer
Spectrum Analyzer (SA) level values depend on the probe type and shall be verified by a
properly working phone sample.
- Start Phoenix Service Software and open FBUS connection.
- Select
→
Scan Product (Ctrl-R)
Wait until phone information is shown in the lower right corner of the screen.
- Set operating mode to “local mode”
- Select
→
Testing
→
RF Controls
- Select
→
Band
→
GSM850 or GSM 900 or GSM1800 or GSM1900
Active unit
→
RX
Operation mode
→
Continuous
RX/TX Channel
→
190 or 37 or 700 or 661