![Nokia NPL-4 Series Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/nokia/npl-4-series/npl-4-series_troubleshooting-instructions_1699328016.webp)
NPL-4/5/RM-104
Company confidential
Troubleshooting Instructions
Nokia Customer Care
Page 16
Copyright
© 2005
Nokia Corporation. All rights reserved.
Issue 2 05/05
Receiver Verification and Troubleshooting
General instructions for RX troubleshooting
Connect the phone to a PC, which has Phoenix Service Software and a dongle installed,
using either
•
Repair jig and DAU-9S (RS232) cable or
•
DAU-9T cable (RS232) or
•
DKU-5 cable (USB)
Connect the phone to a power supply (DC voltage: 4.0V, max. current: 3A) and an RF sig-
nal generator. Switch the phone on.
Start Phoenix Service Software and open FBUS connection.
- Select
→
Scan Product (Ctrl-R)
Wait until phone information (NPL-4 or NPL-5) is shown in the lower right corner of the
screen.
Follow the instructions below.
Measuring RX I/Q Signals using RSSI Reading
- Start Phoenix Service Software and open FBUS connection.
- Select
→
Scan Product (Ctrl-R)
Wait until phone information is shown in the lower right corner of the screen.
- Set operating mode to local mode
- Select
→
Testing
→
RF Controls
- Select
→
Band
→
GSM 850 or GSM 900 or GSM1800 or GSM1900
Active unit
→
RX
Operation mode
→
Burst
RX/TX Channel
→
190 or 37 or 700 or 661
- Select
→
Testing
→
RSSI reading
In the RSSI Reading window the “measuring mode” shall be set on
Sum vector
and the
“reading mode” on
Continuous
.