background image

Nokia M5122

T66250

USER MANUAL

ADSL Bridgeā

Содержание M5122

Страница 1: ...Nokia M5122 T66250 USER MANUAL ADSL Bridgeā ...

Страница 2: ... telephone lines used traditionally for telephone services M5122 enables high speed connections for homes and small offices Figure 1 Nokia M5122 NokiaM5122allowsmultiplePCsequippedwitha10Base TEthernet interface to be connected to a remote network via a Digital Subscriber Line Access Multiplexer DSLAM and an ATM access network It acts as a bridge between the Ethernet LAN and ADSL ATM network inter...

Страница 3: ...1 Interfaces M5122 has one ADSL line interface and four Ethernet interfaces 10Base T It also has a Command Line Interface CLI for management purposes The ADSL line interface is compatible with ITU T G 992 1 specification ADSL line DSL Ethernet ports ETH 1 ETH 2 ETH 3 ETH 4 Command line interface CLI Mains connector Power switch Figure 2 M5122 back panel 2 2 Indicator lights M5122 has eight indicat...

Страница 4: ...s being established On ADSL link is up ETH GREEN Off Ethernet is down On 10Base T Ethernet is functional Blinks Receives traffic from Ethernet COL GREEN Blinks Collisions on the Ethernet Note that it is normal that some collisions occur on the Ethernet STA RED Off OK On Hardware malfunction during startup PWR GREEN Off Power off On Power on ...

Страница 5: ...set your PC s networking options ADSL data services 1 2 3 4 5 Figure 4 M5122 with cables connected ADSL services only 1 Plug the mains power cord to a mains outlet M5122 can be connected to an earthed socket outlet only 2 Switchon M5122 The PWR indicator lights up After a while the red STA indicator blinks and then remains unlit M5122 is now functional 3 Connect the Ethernet cable between your PC ...

Страница 6: ...DSL indicatorstartsblinking ThisindicatesthattheADSLlineisbeing established When the DSL indicator remains lit the line is functional 6 During normal operation PWR and DSL indicators are lit and the Ethernet indicators of the active Ethernet ports blink or remain lit dependingwhether there is traffic or not COLindicatormayblink occasionally during normal operation ...

Страница 7: ...T connector and the Ethernet connector on the M5122 back panel ETH 1 ETH 2 ETH 3 or ETH 4 4 Switch on your PC The indicator corresponding the Ethernet port you connected your PC to becomes green when your PC has started This indicator blinks when there is traffic in the corresponding Ethernet port 5 Connect the ADSL line cable between the DSL connector on the M5122 back panel and the splitter s MO...

Страница 8: ...been switched on Red status STA indicator is lit Switch power off and then on again If the STA indicator remains lit the unit may be faulty ADSL DSL indicator is unlit Make sure that the ADSL line cable has been properly connected between the DSL connector and the wall socket Ethernet ETH indicator is unlit Make sure that the Ethernet cable has been properly connected between your PC s Ethernet in...

Страница 9: ...5122 can also be wall mounted Figure 6 shows the installation procedure 1 Drill two holes 6 mm in diameter on the wall The distance between the holes must be 155 mm Insert the plugs to the holes and fix the screws 2 Mount the modem on the wall as shown in Figure 6 1 2 155 mm 6 mm Figure 6 Wall installation ...

Страница 10: ...ddress must be given to the corresponding interface You can use your PC s web browser software to access the web configuration pages in M5122 To access the web pages you must know the IP address of your M5122 or alternatively the name that your M5122 recognises Note Before using your web browser for configuration you must know the IP address or the name assigned to your M5122 Therearethreewaystofi...

Страница 11: ...ss of your Nokia M5122 in the browser s Open Location field and press Enter If you use the IP address it has to be assigned to a local port or gateway interface Vbridge 3 Type in the username password as requested If no username password is required just click OK to proceed The Nokia M5122 Main Page appears ...

Страница 12: ...viceProviders LocalNetwork Statistics Restart and Save Config takes you to the corresponding page Note When you make modifications to the configuration remember to save the configuration if you want your changes to be active after a restart Figure 7 Main page The Main Page shows you the statuses of the DSL line and Ethernet interfaces Software and hardware versions and the serial number of M5122 a...

Страница 13: ...tion by selecting the connection from the pulldown list Figure 8 shows the page with eth llc encapsulation enabled and Figure 9 with PPTP tunneling enabled Connection name Figure 9 is used for identifying connections The name can be changed and it can be 31 characters long Figure 8 Service Providers page with eth llc encapsulation Figure 9 Service Providers page with PPTP tunneling enabled ...

Страница 14: ... address to the Gateway port Vbridge Note WhenyouclickApply theIPaddressischangedimmediately IftheIP address of the interface you are using changes the connection will be lost You have to reconfigure the IP address of the accessing host For example in Windows programs winipcfg exe or ipconfig exe must be used first to release the old address and then to renew to request new address Figure 10 Local...

Страница 15: ...he DHCP server can be enabled towards LAN and Vbridge gateway interface ports When the DHCP server is enabled up to two scopes address ranges are automatically generated and bound to Vbridge interface Two separate address ranges can be used if more than 253 addresses are required on the local subnet if two non contiguous ranges are needed or if an additional router with DHCP relay is used ontheloc...

Страница 16: ...E Copyright Nokia Networks Oy C33874002SE_A0 15 Figure 11 Local Network DHCP page ...

Страница 17: ...ing select the Routing protocol version from the pull down list and click the Apply button RIP versions 1 and 2 are supported Both v1 and v2 option enables the receiving of both RIPv1 and RIPv2 packets To add a static route type in the Destination network IP address the Subnet mask of the destination network and the Gateway and the Interface through which the destination network can be reached The...

Страница 18: ...17 3 1 5 Statistics page The Statistics page lets you view a selection of M5122 statistics to view statistics of a particular function click the corresponding button and the statistics view is opened on a separate window Figure 13 Statistics page ...

Страница 19: ...Nokia M5122 User Manual E Copyright Nokia Networks Oy C33874002SE_A0 18 3 1 6 Restart page On the Restart page you can reset subsystems and restart M5122 Figure 14 Restart page ...

Страница 20: ...mory and the old configuration cannot be restored through the web interface Figure 15 Save configuration page 4 Features M5122 can operate as a bridge between the Ethernet and the virtual channels of ADSL ATM interfaces 4 1 Bridging M5122 operates as a self learning bridge supporting up to 1024 MAC addresses Bridging in done between the Ethernet 10Base Tinterfaces and the ATM ADSL interface 4 2 AT...

Страница 21: ...only M5122 can act as a Dynamic Host Configuration Protocol DHCP serverfor the PCs on the end user home network In this mode M5122 can assign up to 253 253 consecutive addresses from two separate address ranges that is 253 consecutive addresses per address range to the PCs on the home network Two separate address ranges can be used if more than 253 addresses are required on the local subnet if two...

Страница 22: ...e destination IP address must be M5122 LAN VBRIDGE IP address depending on the configuration PPP packets within PPTP are mapped to the configured VCC M5122 has three different ways to choose the ATM VCC that will be used for tunneling D Automatic chooses the first free VCC D Chooses the VCC number using C number where number is from 1 to 8 C number is typed after the M5122 IP address in PC sPPTP c...

Страница 23: ...at different IP traffic streams are treated fairly in the upstream towards the Internet direction This may be necessary in some cases because theupstreamcapacityoftheADSLlineissomewhatlimitedcompared to the Ethernet bandwidth on the office or home LAN The WFQ CoS function classifies IP traffic streams based on IP address protocol and port fields It is capable of identifying the IP stream from all ...

Страница 24: ...ase T hub Encapsulation DIXv2 transmit IEEE 802 3 and DIXv2 re ceive Ethernet connectors RJ 45 Bridging Bridging Self learning bridge bridges between all inter faces possibility to disable bridging between WAN interfaces MAC table 1024 entries Class of Service Weighted fair queueing Command line interface CLI for local management Physical layer Electrically RS 232 TxD RxD and GND sig nals Data for...

Страница 25: ...terface TFTP UDP IP for software and configuration download Management through payload Service categories UBR Encapsulations RFC 2684 Ethernet LLC Routing Static routes RIPv1 Management proto cols Telnet TCP IP for command line interface TFTP UDP IP for software and configuration download Indicator lights DSL ADSL line status ETH 1 ETH 2 ETH 3 ETH 4 Ethernet activity and status COL Ethernet collis...

Страница 26: ... obtain longer cables for your M5122 1 8 Figure 16 ETH connector PIN Signal Direction M5122 Ethernet MDI signal 1 Rx Receive data 2 Rx Receive data 3 Tx Transmit data 6 Tx Transmit data Table 1 Ethernet interface pin out numbering 1 6 Figure 17 DSL connector PIN Signal 3 DSL1 4 DSL2 Table 2 ADSL interface pin out numbering ...

Страница 27: ...aracteristics of the mains connection are presented in Table 4 Mains connection Voltage 100 240 VAC Frequency 45 65 Hz Power consumption 8 W Table 4 Mains connection 5 3 Ambient conditions EMC and safety Ambient conditions Operating temperature range 0 to 40 C Humidity 10 to 90 non condensing M5122 is for indoor use only M5122 can be connected to an earthed socket outlet only EMC M5122 complies wi...

Страница 28: ...pyright Nokia Networks Oy C33874002SE_A0 27 Immunity EN55024 1998 EMC EN300386 2 1997 Overvoltage ITU T K 21 Safety Safety EN60950 5 4 Copyright note HTTP server Copyright 1996 1997 1998 1999 Michiel Boland ...

Страница 29: ...Nokia M5122 User Manual E Copyright Nokia Networks Oy C33874002SE_A0 28 ...

Отзывы: