1.3 Installing Flexi Zone Micro BTS (FWHR) on a
horizontal pole
The procedure describes the installation on a horizontal pole that is specific for FWHR.
Purpose
Use the Flexi Zone Wall and Pole Mounting Bracket (FMWA) (472858A) and band straps
to install Flexi Zone Micro BTS on a pole. The band straps depend on the chosen pole
diameter. The width of the band straps should be less than ¾" to properly fit into the slots
of the mounting bracket.
Before you start
f
CAUTION! Risk of personal injury.
Ensure that the selected band straps can sustain the device under required
circumstances.
The selected band straps should be rated for outdoor use and be capable of securing
the BTS weight. A certified structural engineer should inspect and approve the
mounting pole and hardware prior to installation.
w
NOTICE:
Flexi Zone Micro BTS equipment must be installed by trained and qualified
service personnel in accordance with all local codes and requirements.
w
NOTICE:
Flexi Zone Micro BTS equipment is intended for installation in a restricted
access location or equivalent.
w
NOTICE:
The BTS interface panel should always face the ground. Any other installation
position might cause overheating and possible damage to the BTS.
Figure 20
Flexi Zone Micro BTS (FWHR) interface panel
RF
BACKHA
UL
STATUS
BHC
BHB
AC
POWER
BLUETO
OTH
InterfacepanelsideofBTS
Installing Flexi Zone Micro BTS
Installing and Cabling Flexi Zone Micro High Power
2x20 W BTS
24
DN09229011
Issue: 02