ANSI ONU safety guidelines
42
7368 ISAM ONT E-240G-B Product Guide
3FE-46261-AAAA-TCZZA
Issue: 01
4.4 Electrical safety guidelines
This section provides the electrical safety guidelines for the ONU equipment.
4.4.1
Power supplies
The use of any non-Nokia approved power supplies or power adapters is not
supported or endorsed by Nokia. Such use will void any warranty or support contract
with Nokia. Such use greatly increases the danger of damage to equipment or
property.
4.4.2
Cabling
The following are the guidelines regarding cables used for the ONU equipment:
•
Use only cables approved by the relevant national electrical code.
•
Use cables suitable for outdoor use for outdoor installation of ONUs.
•
The ONUs have been evaluated for use with external POTS wiring without
primary protection that may not exceed 140 ft (43 m) in reach. However, the power
cable must not exceed 100 ft (31 m).
4.4.3
Protective earth
Earthing and bonding of the ONUs must comply with the requirements of NEC article
250 or local electrical codes.
4.5 ESD safety guidelines
The ONU equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONU equipment.
Note —
The ONUs comply with the U.S. National Electrical
Code. However, local electrical authorities have jurisdiction
when there are differences between the local and U.S.
standards.
Caution —
This equipment is ESD sensitive. Proper ESD
protections should be used when entering the TELCO Access
portion of the ONU.
Release 06.01.01 | June 2019 | Edition 09