Item
Description
Type
Code
SRAM Module (3 pcs
needed inside FPS-8)
SF-12
0080346 (Code includes
one SRAM module)
Note:
More than 32MB SRAM required in FPS-8.
Module jig service concept
This concept is for troubleshooting and RF calibration.
MJ-55 is intended for use with an external power supply.
MJ-55 input voltage: 4 V, m6.5 V.
Ensure that the jumper is set for voltage regulation before the external power supply is connected.
When FPS-8 is used as the power supply (4 V), the jumper should be set to bypass regulator.
EM calibrations including Zocus are only done with JBV-1. Module jig MJ-55 does not support Zocus calibration.
Figure 80 Module jig service concept
Item
Description
Type
Code
1
Module jig
MJ-55
0780413
2
RF cable
XRF-1
0730085
3
Power cable
PCS-1
0730012
4
MBUS cable
DAU-9S
0730108
5
Software protection key
PKD-1
0750018
6
Computer with Phoenix
SSW
JBV-1 service concept
This concept is for BB calibration.
EM calibration including Zocus should be carried out in JBV-1 and DA-44.
RM-51
Service Tools
Nokia Customer Care
9238460 (Issue 1)
Company Confidential
Page 4–25
Copyright ©2005 Nokia. All Rights Reserved.