DECORATIVE EXTRACTOR HOODS
Dear client,
We are sure that the purchase of our extractor hood will fully
satisfy all of your needs.
Please read this instruction manual carefully in order to obtain
the best results from the use of the hood.
INSTRUCTIONS FOR INSTALLATION, MAINTENANCE
AND USE
If you need any technical help or would like more information
about our products, please do not hesitate to contact our official
distributor.
GENERAL INDICATIONS
Before installing and using the hood, be sure that the voltage
(V) and the frequency (Hz) indicated on the feature plate match
the voltage and frequency at the installation site.
The feature plate and technical data are shown on the inside of
the product.
For better performance in extracting fumes we advise that
tubing installed should be of a diameter not less than 120 mm.
We also advise using rigid PVC tubing.
ELECTRICAL CONNECTION
Connect the cord to a socket or double pole switch, which must
have a minimum contact opening distance of 3 mm.
The manufacturer shall not be liable for failure to observe all
safety regulations in force for the correct and normal operation
of electrical parts.
ELECTRONIC SWITCH CONTROL PANEL
This panel is located on the front part of the hood and inclu-
des:
- 3 position motor control switch (1st, 2nd, and 3rd speed)
(Ref. D).
- Lighting control lamp. Fig. 6. (Ref. E).
- Motor control lights. (Ref. G).
- Light switch (Ref. F).
TIMING: To operate the canopy timer, having selected the
speed, press the button for two seconds until the LED light
blinks. The timer will then work for 15 minutes.
At the end of this time, the motor will stop and the light will go
out. If it is still on, and you wish to cancel the timing, press the
timer button once and the motor will stop.
IMPORTANT:
• Do not connect the hood to chimneys, ventilation pipes or
hot air pipes. Before connecting any pipes, consult munici-
pal ordinances on exhaust air and request permission from
the person in charge of the building. Be sure there is ade-
quate ventilation, even in cases where the hood is to be
used simultaneously with another product.
• Never leave frying food unattended since grease can
overheat and catch fire. The risk of fire is even greater in the
case of used oil.
• Never use the hood in areas where devices with exhaust
pipes connected to the outside are already operating unless
perfect ventilation can be guaranteed.
• To avoid the possibility of fire, adhere strictly to all of the
recommendations included here and to the periodic cle-
aning of the grease filters.
• During an electrostatic discharge (ESD) it is possible that
the device will stop working. By switching the device OFF an
ON the device will again work as intended. There is no risk
and no risk will appear.
• If the supply cord of this equipment is damaged, it must
only be replaced by manufacturer or it’s service agent or
similarly qualified person in order to avoid a hazard.
• Never have a lighted flame under the extractor hood.
• The appliance must be placed in such a way, that the
supply plug is accessible.
• The hood must be installed at a minimum distance of 65cm
from the stovetop.
• During climatic conditions causing electrical interference, it
is possible that the device may stop working. By switching
the device OFF and ON the device will resume normal ope-
ration safety.
• This hood is not designed to be used by people (including
children) with reduced physical, sensorial or mental capaci-
ty, or who lack experience or knowledge about it, unless
they have had supervision or instructions on how to use the
hood by someone who is responsible for their safety.
• Children must be supervised to ensure that they do not
play with the hood.
• The evacuated air must not be sent along conduits that are
used to evacuate smoke from devices powered by gas or
other fuels (this does not apply to devices used exclusively
to discharge air inside the room).
• When the extractor hood is turned on at the same time as
other appliances powered by energy other than electricity,
the air outlet must not be greater than 4 Pa (4x10-5 bar).
• Never use the hood in places where appliances are
already operating with outputs connected to the exterior
unless perfect ventilation of the place can be ensured.
• This hood can only be installed over electric or gas hobs
with a maximum of 4 cooking points.
• If the extractor hood is installed over a gas cooking
GB