Use and Maintenance Manual model “A13V - C ZENITH & A13 V PLUS ZENITH”
9
ENGLISH
ENGLISH
3.6 EXAMPLES OF CORRECT INSTALLATION
installation of the product (A) necessary for the hori-
zontal section for connection to an existing
chimney flue. Based on a slope of 3-5%, to reduce
ash deposit in the horizontal pipe section which must
not be over 3m (1). The existing chimney flue must
be inspectionable (2).
Installation of the product (B) requires an insulated
chimney flue
(3) with an internal diameter of no less
than 100mm, since all the smoke piping was assem-
bled outside the home.
Installation of the product (C) requires a single wall
chimney flue
(4) for the section inside the home.
Relating to the part placed in the attic, you are ad-
vised to install a chimney flue Ø120mm, with perfo
-
ration for passage of the piping, extended to:
•
minimum 100mm around the pipe if in contact
with inflammable parts such as cement,
bricks, etc.;
•
minimum 300mm around the pipe (or as
described in the plate data) if in contact with
flammable parts such as wood etc.
In both cases, insert adequate insulation (5) be-
tween the chimney flue and the attic.
You are advised to check and comply with the
plate data of the chimney flue, in particular the safe
distances from combustible materials.
The previous rules also apply for holes made on
walls.
On the lower part of the chimney flue, for all
3
installations, a “T” fitting (6) was assembled with an
inspection plug (7), as well as on the inlet of the
chimney flue.
The upper part of the chimney flue, for all
3 installa-
tions, has a wind-proof chimney pot (8) assembled.
In the home, for all 3 installations, a grate is planned
to guarantee correct oxygenation of the premises
where the product is positioned.
Grate not necessary if appliance is hermetically
sealed.
It is not recommended to install a 90° curve as an in-
itial section which would quickly cause ash to block
smoke passage, causing draught problems
in the appliance.
9
6
7
7
A
1
2
3
3
4
5
8
8
8
6
9
9
6
7
In the event of particular atmospheric conditions
and/or hostile draught conditions, the product can
overcome these situations provided due installation
measures are in place, for example a wind-proof
chimney pot.
B
C
6
Содержание A13 C ZENITH
Страница 1: ...EN Installation use and maintenance manual A13 V ZENITH A13 C ZENITH A13 V PLUS ZENITH...
Страница 35: ......