Use and Maintenance Manual model “A13V - C ZENITH & A13 V PLUS ZENITH”

 

29 

ENGLISH

ENGLISH

17 DESCRIPTION OF ALARMS

ALARM CODE

REASON

01

BLACK OUT

No power during the work phase

SOLUTION

Press the switch off key and repeat 

switch on of the appliance
If the problem persists, contact the Support 

Service.

ALARM CODE

REASON

02

 

NO 

SWITCH ON

The pellet tank is empty.

Calibration of the pellets and suction during 

the start-up phase inadequate.
Ignition resistor faulty or out of position

SOLUTION

Check there are pellets in the 

tank. If necessary, load.
If the problem persists, contact the Support 

Service

ALARM CODE

REASON

03

PELLETS FINISHED

The pellet tank is empty.

The gearmotor is not loading pellets

Lack of pellets loading

SOLUTION

Check there are pellets in the 

tank. If necessary, load
Empty the tank to check that 

there are no objects inside it.
Adjust, by increasing the load of pellets, from 

“P/E MIX”
If the problem persists, contact the Support 

Service

ALARM CODE

REASON

04

SMOKE TEMPERA-

TURE

Combustion in the brazier is not optimal as it 

is clogged or the inner passages of the ap-

pliance are clogged.
The tangential fan (if present) is 

not working properly or is damaged.

SOLUTION

Switch the product off and back on again, 

activating the cleaner; adjust the 

combustion with the “P/E mix”.
If the problem persists, contact the Support 

Service

ALARM CODE

REASON

05

EXTRACTOR 

ROTATIONS NOT 

RESPECTED

The rotations of the smoke extractor show a 

loss of efficiency due to obstruction of 

the fan or a drop in voltage.

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

06

FAULTY SMOKE 

EXTRACTOR

No power supply to the smoke extractor

The smoke extractor is blocked

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

07

GEARMOTOR  

ROTATIONS NOT 

RESPECTED

PELLET LOADING

The rotations of the gearmotor present a 

loss of efficiency due to a drop in voltage.

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

08

PELLET LOADING 

GEARMOTOR 

FAULT 

Gearmotor encoder not working or not 

connected correctly

No power to gearmotor

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

09

PELLET LOADING 

AUGER 

BLOCKED

Possible foreign body or sawdust preventing 

correct movement.

SOLUTION

Empty the tank and check for foreign bodies.

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

10

PELLET 

LOADING AUGER 

POWER SUPPLY 

DEFECT

No power supply or power supplied by elec-

tronic control unit not 

correct

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

11

MINIMUM 

PRESSURE PASCAL

The sensor does not detect negative air 

pressure inbound of the appliance.

SOLUTION

Check the door and ash pan are   

closed correctly, check if the air intake 

tube is obstructed. 

If the problem persists, ccontact the Support 

Service.

Содержание A13 C ZENITH

Страница 1: ...EN Installation use and maintenance manual A13 V ZENITH A13 C ZENITH A13 V PLUS ZENITH...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...ld device keys 14 7 3 Description of handheld device display 14 7 4 Flat battery signalling 15 7 5 Concise icons diagram 15 8 Menu browsing 16 9 First start up instructions 16 9 1 Date and time settin...

Страница 4: ...ing activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the...

Страница 5: ...tenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user...

Страница 6: ...nment making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negat...

Страница 7: ...other rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary...

Страница 8: ...ation In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the i...

Страница 9: ...flammable parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in parti...

Страница 10: ...act with hot parts and must remain accessible after installation To carry out electrical connection proceed as de scribed below connect the power supply cable on the back of the appliance connect the...

Страница 11: ...nt product operation is not guaranteed In this phase the authorised technician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broken pellet r...

Страница 12: ...utilizzato per la costruzione dell oggetto rappresentato n venire comunicato a terzi o riprodotto La Societ proprietaria tutela i propri diritti a rigore di legge All proprietary rights reserved by N...

Страница 13: ...el is loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to...

Страница 14: ...wing chapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as report...

Страница 15: ...the appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of t...

Страница 16: ...Scroll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar...

Страница 17: ...inhibits manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9...

Страница 18: ...eplace as soon as the temperature in the premises goes under the required setting optimisation of combustion and acoustic comfort During first start up of the product unpleasant odours may occur or sm...

Страница 19: ...AND BY screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set...

Страница 20: ...Thermostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to fol...

Страница 21: ...e the switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte na...

Страница 22: ...ELLET and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you wa...

Страница 23: ...at is installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing t...

Страница 24: ...se simply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct cha...

Страница 25: ...ne to channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external...

Страница 26: ...ture setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the L...

Страница 27: ...TART PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlight...

Страница 28: ...or controlling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a...

Страница 29: ...Service ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the proble...

Страница 30: ...blem persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank...

Страница 31: ...urfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damage to the surface of the product 18 1 CLEANING THE FIREPLACE Open the fire doo...

Страница 32: ...t and which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations mu...

Страница 33: ...ct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chambe...

Страница 34: ...AL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION tech...

Страница 35: ......

Страница 36: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0012N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: