10.4 VENTILATION MANAGEMENT 

(if optional)

The products of the range with optional ventilation, 

taking advantage of the natural convection system 

which guarantees a considerable amount of heat in 

the ambient, in total absence of noise. However, 

the possibility exists, by accessing the menu outlined 

below, to enable optional ventilation according to 

the desired power.

OPERATING PROCEDURE:

 MENU >> SET USER >> VENTILATION

Access the menu by pressing key
Scroll the items to SET USER with the key  
Access the menu by pressing key
First item in the “VENTILATION” menu, key
The screen appears with adjustment of 

ventilation as in the figure below.

OK

OK

OK

OK

Confirm with key  

To return to the STAND-BY screen, use the 

key       , repeating the operation multiple times.

Edit the ventilation power, keys

   0 - ventilation disabled;

1-7 - ventilation setting range;

 PS - ventilation follows power to the fireplace  

        set on the appliance.

If the PS function is not set, the fan 

is always restricted by the power of 

the product.

11 DESCRIPTION OF THE MENU FUNCTIONS

This chapter describes the user menu functions, useful 

to improve some comfort related aspects of the user 

and/or operation of the product.

11.1 THERMOSTAT WITH TIMER FUNCTION

With the Thermostat with timer function, you can: 

program for each day of the week automatic switch 

on and off of the product, with 4 independent time 

intervals (PROGRAM 1 - 2 - 3 - 4).

The steps are outlined below to follow, starting with 

the STAND-BY screen, to access the relevant menu.

OPERATING PROCEDURE 2:

 MENU >> SET USER >> SETTINGS >> POWERFUL

Access the menu by pressing key
Scroll the items to SET USER, key  
Access the menu by pressing key
Scroll the items to SETTINGS with the key  
Access the menu by pressing key
Scroll the items to POWERFUL with the key
On the POWERFUL menu item, key
The screen appears with adjustment of the 

setting parameters, as in the figure below.

OK

OK

OK

OK

Edit the switch on and switch off times, as well as 

enabling the days of the week, keys  

During editing, remember that:

• to return to the previous data, without saving 

   the last data changed, press the key   

• 

if you intend changing a single datum, having ter

   minated the change, press the key       multiple 

   times until you exit the function described in the 

   paragraph.
To return to the STAND-BY screen, use the 

key       , repeating the operation multiple times.

OK

If the time slot is set with the POWERFUL function, the 

data setting in “Enable Powerful” must be “TIMER”. If 

the value is set to "ON”, the time slot is inhibited up to 

its disabling (OFF). 

The POWERFUL function, if both the time slot and the 

manual tick are enabled, inhibits AUTO manage-

ment up to its disabling. 

Confirm each data change using the 

key       until 

you exit the SETTINGS screen.

OK

Содержание A10 C PLUS QUADRA

Страница 1: ...EN Installation use and maintenance manual A10 V PLUS QUADRA A10 C PLUS QUADRA...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...vice keys 14 7 3 Description of handheld device display 14 7 4 Flat battery signalling 15 7 5 Concise icons diagram 15 8 Menu browsing 16 9 First start up instructions 16 9 1 Date and time setting 16...

Страница 4: ...ctivity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the manu...

Страница 5: ...ce non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user in a...

Страница 6: ...making it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negative p...

Страница 7: ...r rooms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for i...

Страница 8: ...In Italy only roof discharge is permitted 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following characteristics the smoke outlet section must be at least double the inner...

Страница 9: ...able parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in particular...

Страница 10: ...ith hot parts and must remain accessible after installation To carry out electrical connection proceed as de scribed below connect the power supply cable on the back of the appliance connect the cable...

Страница 11: ...ch excellent product operation is not guaranteed In this phase the authorised technician should completely and accurately clean the smoke pipes check the sealing status of all the gaskets remove broke...

Страница 12: ...a il presente disegno non potr essere utilizzato per la costruzione dell oggetto rappresentato n venire comunicato a terzi o riprodotto La Societ proprietaria tutela i propri diritti a rigore di legge...

Страница 13: ...loaded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to cent...

Страница 14: ...chapter carefully relating to use of the receiver and the handheld device as well as their related functions INFORMATIVE NOTE frequency bands and transmitted power used by the equipment as reported in...

Страница 15: ...appliance see Concise icons diagram 7 4 FLAT BATTERIES SIGNAL If batteries are flat the display presents a symbol which indicates their limit status however maintaining the functions enabled of the ha...

Страница 16: ...ll the items to SETTINGS with the key Access the menu by pressing key Scroll the items to TIME DATE with the key On the TIME DATE menu item key The screen appears to adjust the time and calendar as in...

Страница 17: ...its manual management of the op tional fan with the exception of the fan setting on OFF In this case the appliance autonomously only manages power to the fireplace Ventilation remains disabled 9 5 FIR...

Страница 18: ...mode also en sures if the home has a good energy class a fuel saving through intelligent switch off of the product reaching or required of the desired setting The procedure follows to enable the funct...

Страница 19: ...Y screen use the key repeating the operation multiple times OK OK Edit the value with the keys The logic relating to this type of management is as follows USER the user reserves the right to set the a...

Страница 20: ...ostat with timer function you can program for each day of the week automatic switch on and off of the product with 4 independent time intervals PROGRAM 1 2 3 4 The steps are outlined below to follow s...

Страница 21: ...switch on phase of the appliance after accurate cleaning was conducted of the hopper pellet con tainer to remove sawdust which over time is creat ed on the base See the chapter Routine mainte nance o...

Страница 22: ...and 3 EXTRACTION was set this kind of setting results from the fact combustion is lacking oxygen and the pellets are small in size compared to the average 2cm OK Select the type of screen you want to...

Страница 23: ...installed has not yet reached the temperature required the writing T OFF if in the room the ambient temperature is reached 11 6 LANGUAGE Based on the destination country or the user acquir ing the pr...

Страница 24: ...mply approach the appliance to re establish communication 12 CHANNEL where planned The products of the range equipped with channel ling are in two types single duct channelling or double duct channell...

Страница 25: ...channel with the help of an optional ambient probe provided on request of Nobis s r l not supplies as standard OK If the flag is enabled for channelling temperature management with the external therm...

Страница 26: ...setting from the handheld device but rather from the external ther mostat Having confirmed setting of the RH channelling confirm with the key and re peat the same sequence of operations for the LH cha...

Страница 27: ...PHASE DESCRIPTION Ambient setting in MAN therefore the appliance only works with the power to the fireplace set never going to saving MAN WORK 14 FUNCTIONS CONCISE DIAGRAM Edit the data highlighted us...

Страница 28: ...ntrolling correct combustion For safety purposes while waiting for the technician the appliance is set to saving mode The maximum smoke temperature threshold has been reached the appliance for a perio...

Страница 29: ...ice ALARM CODE REASON 05 EXTRACTOR ROTATIONS NOT RESPECTED The rotations of the smoke extractor show a loss of efficiency due to obstruction of the fan or a drop in voltage SOLUTION If the problem per...

Страница 30: ...persists contact the Support Service ALARM CODE REASON 16 PELLET TANK DOOR OPEN During the pellet loading phase of the product the tank door was not closed properly SOLUTION Check the pellet tank door...

Страница 31: ...are cold to touch ensure the combustion ash is completely out To clean the surfaces on the painted metal parts use a cloth soaked in water and soap Use of abrasive detergents or diluents causes damag...

Страница 32: ...which could damage the appliance used for cleaning The cleaning operations depend on the quality of the pellets used and the frequency of use of the product It can happen that such operations must be...

Страница 33: ...pliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chimney flue 1 SE Combustion chamber 2 3...

Страница 34: ...SET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT K J PC CONNECTION technical support only USB CONNECTION technical...

Страница 35: ......

Страница 36: ...N 11 25037 Pontoglio BS www nobisfire it Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products without prior warnin...

Отзывы: