background image

 
 

9        65_Apparent_Wind_Monitor_FR_11

 

4.1  Wiring from the Apparent Wind Monitor 

To open the housing, you access the screws located below the two side flaps. Use a 
cross-head screwdriver to open the housing.   
Run  the  sensor’s  cables  through  the  dedicated  glands.  Use  silicone  grease  to 
facilitate the cables passage. Strip the cable over 10 cm and put a heat-shrink sleeve 
on the braid to prevent short-circuits. Tin the cables over 5mm and place them on the 
relevant terminals. Add a plastic cable tie next to the gland, to protect the connection 
in case of accidental traction on the cables.  
 
Connection
:  
 
- Bus cable welded on the board  
-  The  3  wind  sensors  and  the  mast  angle  sensor  are  connected  to  the  terminal  on 
dedicated positions. White wire: 12V; braid: GND; black wire: DATA.  
The main wind sensor must be connected to AG1 input.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
External connection:  

Connect the bus cable to a Topline junction box as follow: 

 

White = +12 V 

 

Braid = GND  

 

Black = Data  

 

Red = NMEA0183 output  

 

Yellow = NC 

 

Green = NC 

 

 

 

 

 

Содержание 90-60-398

Страница 1: ...Zi de Kerandr Rue Gutenberg 56700 HENNEBONT www nke marine electronics fr APPARENT WIND MONITOR Part number 90 60 398 USER MANUAL INSTALLATION SHEET V1 1...

Страница 2: ...ultigraphic 5 3 1 2 Setup with a Multidisplay 6 3 2 Mast angle setup 6 3 2 1 Mast angle sensor setup with a MULTIGRAPHIC 6 3 2 2 Setting up the Mast Angle with a Multidisplay 7 4 Installation 8 4 1 Wi...

Страница 3: ...lectrically isolate the mast cable and the mast head unit from the rest of the Topline Bus installation In case of a short circuit in the cable or the wind sensor the installation is not affected and...

Страница 4: ...ent Wind Monitor must be installed close to the mast foot refer to Installation chapter The boat s attitude behaviour data combined with the mast height already entered via a Multigraphic V2 4 or newe...

Страница 5: ...tables are integrated in the Apparent Wind Monitor which broadcasts them at the installation start 3 1 Setting up the mast height The mast height is required for data denoising The value is the measu...

Страница 6: ...staller Enabling the mast angle function if a sensor is connected The mast angle function is disabled by default factory settings on the Apparent Wind Monitor With the help of the Toplink software ena...

Страница 7: ...e part 3 2 2 Setting up the Mast Angle with a Multidisplay The mast angle setup is done with a Multidisplay in the same way as with a Multigraphic In the Sensor menu select Mast Angle set an offset va...

Страница 8: ...ing It must be perfectly horizontal for the best denoising result See below for a reverse mounting Standard mounting Front To the boats bow Gravity Bulkhead mount cables downwards and horizontal paral...

Страница 9: ...event short circuits Tin the cables over 5mm and place them on the relevant terminals Add a plastic cable tie next to the gland to protect the connection in case of accidental traction on the cables C...

Страница 10: ...lation includes a mast foot junction box for the mast head unit connection only the wind sensor s mast cable will be connected to that box The mast head unit cable is no longer connected to the Toplin...

Страница 11: ...11 65_Apparent_Wind_Monitor_FR_11 5 SPECIFICATIONS OF THE APPARENT WIND MONITOR 5 1 Dimensions mm of the housing of Apparent Wind Monitor...

Страница 12: ...38400 bauds Weight 360 gr with cable Operational consumption 12 V 100mA Topline bus power cable 5 5mm 4 wires ground length 3m Wind sensors connections 3 wind units inputs 3 wires Mast Angle connecto...

Страница 13: ...13 65_Apparent_Wind_Monitor_FR_11 6 APPARENT WIND MONITOR FIRMWARE HISTORY REV Date Information V1 0 29 06 2018 Original version V1 1 24 01 2019 True Wind Tables added...