background image

 
 

4        65_Apparent_Wind_Monitor_FR_11

 

 

- Automatic:  Depending  on  the  sensors'  condition,  the  Apparent  Wind 

monitor selects the sensor to be used, giving priority to the main sensor, Nr 1.  
In  case  of  a  short  circuit  on  the  Input  1,  the  Apparent  Wind  Sensor  switches 
automatically to Input 2 if there is a sensor connected to that port.  
 
Mounting example: Carbowind is on the Input 1 as main wind sensor and AG HR on 
Input 2 as backup sensor.  
  

2.3   Wind data denoising 

This function is available only with HR type sensors (Carbowind and AG HR). 

Denoising is processed with the help of a 6 axes IMU (

Inertial Measurement Unit

) 6 axes 

integrated in the Apparent Wind Monitor, providing instant boat's attitude/behaviour. 
Therefore,  the  Apparent  Wind  Monitor  must  be  installed  close  to  the  mast  foot 
(refer to Installation chapter) 

The  boat's  attitude/behaviour  data  combined  with  the  mast  height,  already  entered 
via a Multigraphic V2.4 (or newer), are used to correct the raw wind data coming from 
the  mast  head  unit.  The  result  gives  "denoised"  apparent  wind  angle  and  apparent 
wind speed.  

 

2.4   LEDs Status 

Three LEDs wind sensor and one LED mast angle are featured on the front.  

- Status of the wind sensor LED AG1 – AG2 – AG3: 

    Green:  Wind  sensor  manually  or  automatically  selected  and  correct  operation  of 

that sensor.  

Red: relevant sensor is faulty. Selected sensor is faulty or not present.  

Off: Not selected  

 

- LED for mast rotation sensor: 
- Fixed green when the function is enabled and the sensor connected 

          - Flashing red when the function is activated and the sensor not connected or 
out of order 
         - Off when the function is disabled 

 

 
 

Wind sensor Led  

 
 
 
 

Mast rotation sensor Led 

 
 
 
 
 

Содержание 90-60-398

Страница 1: ...Zi de Kerandr Rue Gutenberg 56700 HENNEBONT www nke marine electronics fr APPARENT WIND MONITOR Part number 90 60 398 USER MANUAL INSTALLATION SHEET V1 1...

Страница 2: ...ultigraphic 5 3 1 2 Setup with a Multidisplay 6 3 2 Mast angle setup 6 3 2 1 Mast angle sensor setup with a MULTIGRAPHIC 6 3 2 2 Setting up the Mast Angle with a Multidisplay 7 4 Installation 8 4 1 Wi...

Страница 3: ...lectrically isolate the mast cable and the mast head unit from the rest of the Topline Bus installation In case of a short circuit in the cable or the wind sensor the installation is not affected and...

Страница 4: ...ent Wind Monitor must be installed close to the mast foot refer to Installation chapter The boat s attitude behaviour data combined with the mast height already entered via a Multigraphic V2 4 or newe...

Страница 5: ...tables are integrated in the Apparent Wind Monitor which broadcasts them at the installation start 3 1 Setting up the mast height The mast height is required for data denoising The value is the measu...

Страница 6: ...staller Enabling the mast angle function if a sensor is connected The mast angle function is disabled by default factory settings on the Apparent Wind Monitor With the help of the Toplink software ena...

Страница 7: ...e part 3 2 2 Setting up the Mast Angle with a Multidisplay The mast angle setup is done with a Multidisplay in the same way as with a Multigraphic In the Sensor menu select Mast Angle set an offset va...

Страница 8: ...ing It must be perfectly horizontal for the best denoising result See below for a reverse mounting Standard mounting Front To the boats bow Gravity Bulkhead mount cables downwards and horizontal paral...

Страница 9: ...event short circuits Tin the cables over 5mm and place them on the relevant terminals Add a plastic cable tie next to the gland to protect the connection in case of accidental traction on the cables C...

Страница 10: ...lation includes a mast foot junction box for the mast head unit connection only the wind sensor s mast cable will be connected to that box The mast head unit cable is no longer connected to the Toplin...

Страница 11: ...11 65_Apparent_Wind_Monitor_FR_11 5 SPECIFICATIONS OF THE APPARENT WIND MONITOR 5 1 Dimensions mm of the housing of Apparent Wind Monitor...

Страница 12: ...38400 bauds Weight 360 gr with cable Operational consumption 12 V 100mA Topline bus power cable 5 5mm 4 wires ground length 3m Wind sensors connections 3 wind units inputs 3 wires Mast Angle connecto...

Страница 13: ...13 65_Apparent_Wind_Monitor_FR_11 6 APPARENT WIND MONITOR FIRMWARE HISTORY REV Date Information V1 0 29 06 2018 Original version V1 1 24 01 2019 True Wind Tables added...

Отзывы: