Step 3:

  Plug Ethernet cable to the Ethernet port (RJ-45) on the SNMP web 

manager.

Step 4:

  Use one more Ethernet cable. Connect one end to the sensor port on 

the SNMP web manager and the other end to the optional environ

-

mental monitoring device.

Chart 2-2

2.4 Configuration

1.  Please install SNMP web manager wizard in your PC. After software is in

-

stalled successfully, the Installer will leave a shortcut icon on your desktop.

Chart 2-4

2.  Enter specific IP address to search all SNMP devices in LAN. The SNMP 

web manager is default applied static IP address as 192.168.102.230, 

default subnet mask as 255.255.255.0, and default gateway as 

192.168.102.254. Users can modify IP address or apply DHCP mode 

through web server of SNMP web pro card, SSH Client or SNMP Web 

Manager.

Chart 2-5

3.  User can modify IP setting, online upgrade, password management, and 

static trap address setting in SNMP Web Manager screen. It is neces

-

sary to enter password for any medications. The default password is 

12345678.

Please check SNMP Web Manager User Manual for detailed configuration.

2.5 Monitoring

There are two ways to monitor:
1.  Double click the selected device from the device list (refer to Chart 2-5) 

to open web page as Chart 2-6 a. Or simply enter https address 

(http://192.168.107.234) in web browser to access web server directly. 

Refer to Chart 2-6 b.

Chart 2-6 a

Содержание ACUP-SN000MP-AZ01B

Страница 1: ...SNMP Card WP User manual ACUP SN000MP AZ01B Before using this product carefully read all product documentation and retain it for future reference 111 0...

Страница 2: ...ion Menu 10 4 1 Information 10 4 1 1 Status 10 4 1 2Basicinformation 10 4 2 UPS setting 11 4 2 1Parameterssetting 11 4 3 Control 13 4 3 1Real timecontrol 13 4 4 System configuration 13 4 4 1 Web user...

Страница 3: ...port data transmission port Golden finger connects to UPS slot Ethernet port status LEDs Jumper setting to restore default setting Ethernet port status LEDs 100M LED Green On Port is operating at 100M...

Страница 4: ...30 default subnet mask as 255 255 255 0 and default gateway as 192 168 102 254 Users can modify IP address or apply DHCP mode through web server of SNMP web pro card SSH Client or SNMP Web Manager Cha...

Страница 5: ...includes function menu login section and main screen Refer to Chart 3 1 Chart 3 1 A SNMP web pro GUI version B Function Menu It offers complete tool set for navigation and setting the GUI C Main Scree...

Страница 6: ...ing for bypass mode and voltage range setting for ECO mode Select UPS setting Parameters setting Refer to Chart 4 4 Chart 4 4 NOTE Different UPSs may access different parameter setting 1 Select the fu...

Страница 7: ...et setting Users can set limited backup time for P1 outlets when UPS is on battery mode Battery numbers setting Set battery numbers in parallel Voltage and frequency range for bypass mode Set acceptab...

Страница 8: ...ccessfully sent to specific recipients it will pop up a suc cessful message on operated PC Otherwise it will pop up a failure dialog to indicate there is an error for parameter setting 4 You may decid...

Страница 9: ...hardware support for remote PCs to implement this function 4 4 5 Shutdown It is to remotely shut down specific PCs with Shutdown Wizard This function is only available to integrate with Shutdown Wiza...

Страница 10: ...king this checkbox it will send alarm E mail when any event occurs on the local UPS Send SMS while any UPS event occurs When clicking this checkbox in the event of an alarm condition occurring a messa...

Страница 11: ...p IP address SNMP UDP port add delete snmpv3 user account and restore the factory settings NOTE Some modifications are required to restart snmp server to become effective Select System Configuration S...

Страница 12: ...as csv file The event log includes UPS warnings fault info EMD warnings UPS oper ation logs from web users or ViewPower pro users All logs are recorded in flash memory of web card by month It s safely...

Страница 13: ...the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical a...

Страница 14: ...Memo Memo...

Страница 15: ......

Отзывы: