background image

CHRONOTRONIX V400 NIXIE TUBE CLOCK 

2006

 

 

9.9  Submenu 2.7: Setting Switch on Time for Night 

Power-Down Mode 

This submenu is similar to submenu 2.6 but it shows the time the 
display is switched on. 
If you do not want to use the night power-down mode, set both 
times  (submenu  2.6  and  2.7)  equal.  Accordingly,  the  display 
shall never switch off. 
 
Setup Example: 

  The shall automatically switch on at 06:45:00 o'clock 

  Clock is in display mode. 

  Press button 1 (short) to enter the main menu 2. 

  Clock stops and displays the current set alarm time. 

  Press button 2 six times to reach submenu 2.7 

  Press button 1 (short) to enter the submenu 2.7. 

  Press button 2 (to count up) and button 3 (to count down) to 

set the first digit (to '0') 

  Press button 1 (short) to jump to the second digit 

  Press button 2 and button 3 to set the second digit (to '6') 

  Press button 1 (short) to jump to the third digit 

  Press button 2 and button 3 to set the third digit (to '4') 

  Press button 1 (short) to jump to the fourth digit 

  Press button 2 and button 3 to set the fourth digit (to '5') 

  Press button 1 (short) to jump to the fifth digit 

  Press button 2 and button 3 to set the fifth digit (to '0') 

  Press button 1 (short) to jump to the sixth digit 

  Press button 2 and button 3 to set the sixth digit (to '0') 

  Press  button  1  long  time  (1  second)  to  leave  the  submenu 

2.7. 

  Press button 1 long time (1 second) to leave the main menu 

2. 

  Clock starts running in display mode. 

 

9.10  Submenu 2.8: Blanking of the Leading Zero 

The leading zero of the time display (example: 

0

1:00:00) can be 

disabled. This means that instead of showing '0' the first tube is 
completely switched off.  
If this submenu is entered, the display shows 08:00:xx whereas 
‘xx’ indicates the following: 
00: Blanking is not active (first ’0’ will be displayed) 
01: Blanking is active (first ’0’ will not be displayed). This setting 

does not influence the way the date is displayed. (example: 
The date ’01.01.05’ will be displayed completely) 

 
Setup Example: 

  The value in this menu shall be set to 01. 

  Clock is in display mode. 

  Press button 1 (short) to enter the main menu 2. 

  Clock stops and displays the current set alarm time. 

  Press button 2 seven times to reach submenu 2.8 

  Press button 1 (short) to enter the submenu 2.8. 

  Press button 2 (to count up) and button 3 (to count down) to 

set the value to '01') 

  Press  button  1  long  time  (1  second)  to  leave  the  submenu 

2.8. 

  Press button 1 long time (1 second) to leave the main menu 

2. 

  Clock starts running in display mode. 

 

9.11  Submenu 2.9: Setting of Cathode Poisoning 

Prevention 

Nixie  tubes  have  an  unwanted  side  effect  called  'cathode 
poisoning' causing metal molecules of glowing cathodes (digits) 
to  attach  to  non  glowing  cathodes.  This  finally  causes  death  of 
the tube. To avoid this effect non/seldom glowing cathodes have 
to be switched on from time to time. Since the cathode poisoning 
varies  between  different  types  of  tubes  Chronotronix  Nixie 
Clocks do have an adjustable cathode poisoning prevention. 
 

In  basic  settings  Chronotronix  Nixie  Clocks  are  already 
preset! Usually, adjusting is not necessary! Please only alter 
the values for a reason. 

 
The switch on of the non glowing digits will be reached by a fast 
scrolling through the digits one after another. This feature can be 
set in duration and frequency of scrolling.  

If  this  submenu  is  entered  display  shows  09:xx:yy  whereas  xx 
and yy indicates the following: 
xx:  frequency, in minutes between scrolling (adjustment range: 

00-59min) 

yy:  Duration of scrolling (adjustment range: 00-59s) 
 
For example, if 09:10:06 is set digits will be scrolled through 
every 10 minutes for 6 seconds. 
 
Settings remark for this menu:  
Clock type V400-ZM1032: 
In basic settings this type is preset to 09:00:00. With these tubes 
cathode poisoning prevention is 

not necessary

. These tubes 

already contain materials avoiding cathode poisoning effects. 
 
Clock type V400-B5025 
With this model the submenu is preset to 09:10:06. In case you 
want to change values in this submenu the following chart could 
be helpful. 

Again: usually it is not necessary to alter values. 

 

 
Values xx can be altered. 
Values  in  column  'minimum  yy  [s]'  are 
standards. One should not fall below that 
value.  A  higher  value  of  yy  results  in  a 
lower cathode poisoning effect. 
If xx and yy is set to 00 cathode poisoning 
prevention is disabled. 
 

 
Remark: 
Should  tubes  show  cathode  poisoning  you  should  increase 
values of yy before looking into replacing tubes. 
 
Setup Example: 

  Cathode poisoning prevention shall be set to 09:15:10 

  Clock is in display mode. 

  Press button 1 (short) to enter main menu 2. 

  Clock stops and shall display the current set alarm time. 

  Press button 2 eight times to reach submenu 2.9 

  Press button 1 (short) to enter the submenu 2.9. 

  Press button 2 (to count up) and button 3 (to count down) to 

set the third digit (to '1') 

  Press button 1 (short) to jump to fourth digit 

  Press button 2 and button 3 to set fourth digit (to '5') 

  Press button 1 (short) to jump to fifth digit 

  Press button 2 and button 3 to set fifth digit (to '1') 

  Press button 1 (short) to jump to sixth digit 

  Press button 2 and button 3 to set sixth digit (to '0') 

  Press button 1 long time (1 second) to leave submenu 2.9. 

  Press button 1 long time (1 second) to leave main menu 2. 

  Clock starts running in display mode. 

 

xx [min] 

minimum 

yy [s] 

10 

15 

20 

30 

11 

40 

15 

50 

18 

60 

22 

Отзывы: