![Nivus OCM PRO CF Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nivus/ocm-pro-cf/ocm-pro-cf_instruction-manual_1696992026.webp)
Instruction manual
OCM Pro CF
page 26
OCM Pro CF - Rev. 09 as of 07.06.2016
®
Fig. 6-10
Echo signal images and evaluation
Based on the beam angle, the interval between both transmitted signals and the
lag of the signal pattern therefore in each single measurement window the flow
velocity can be determined.
Stringing the single flow velocities together mathematically results in the flow
profile of the acoustic path which then is indicated on the OCM Pro display and
can be read there for inspection and control purposes.
Fig. 6-11
Investigated flow profile
If there are appropriate banking distances on the measurement place available,
based on the known channel geometry and the velocity distribution a
3-dimensional flow distribution can be rendered (see Fig. 6-12) (> finite ele-
ment< principle.