Instruction Manual
NivuFlow 550
page 28
rev. 00 / 12.04.2017
Installation and Connection
14 Installation Instructions
During the installation, ensure that the following instructions regarding ESD and installation
place.
Â
Ü
Never operate the device without the four blue plastic cover strips.
Â
Ü
Follow applicable legal or operational guidelines.
Improper handling can result in injury and/or damage to the equipment.
WARNING
Danger from electrical current
Without the four blue plastic cover strips the protection against electrical shock is not guar-
anteed.
Do not operate the device without the four blue plastic cover strips.
Non-observance may result in personal injuries.
14.1 Hints on how to avoid electrostatic discharge (ESD)
ESD risks
Maintenance procedures which do not require power supply of the instrument shall not be
executed before the unit has been disconnected from mains power in order to minimise
danger and ESD risks.
Disconnect the NivuFlow from mains power.
The sensitive electronic components inside the unit may get damaged by static electricity. The
manufacturer recommends the following steps to prevent the device from getting damaged due
to electrostatic discharge:
Â
Ü
Discharge static electricity from your body before touching the instrument’s electronic
components.
Â
Ü
Avoid unnecessary movements to reduce the risk of building up static electricity.
14.2 Choosing the installation place
The NivuFlow with DIN rail fastening is conceived for installation in switching cabinets.
Â
Ü
Pay attention for adequate ventilation at the installation place, such as fans or heat
exchangers.
Â
Ü
During installation make sure that possibly existing separating devices (power switch)
remain to be easily accessible.
It can be also installed in field enclosures or similar. Due to the protection degree,
NivuFlow 550 is not suitable to be installed directly on site without protective measures. To do
so, use the optionally available field enclosure by NIVUS.
For safe installation on the mounting place make sure to take the following precautions:
Â
Ü
Protect the transmitter from direct sunlight. Install a sun shading if required.