Chapter
3: Web Management
Diagnostics - VeriPHY
PoE Switch User Manual | 310
3.3.3. Diagnostics - VeriPHY
This page is used for running the VeriPHY Cable Diagnostics for 10/100 and 1G copper ports.
Press
the “Start” button to run the diagnostics. This will take approximately 5 seconds. If all
ports are selected, this can take approximately 15 seconds. When completed, the page
refreshes automatically, and you can view the cable diagnostics results in the cable status
table. Note that VeriPHY is only accurate for cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running
VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until
VeriPHY is complete.
The ports belong to the currently selected stack unit, as reflected by the page header.
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port:
Port number
Pair:
The status of the cable pair.
OK - Correctly terminated pair
Open - Open pair
Short - Shorted pair
Short A - Cross-pair short to pair A
Short B - Cross-pair short to pair B
Short C - Cross-pair short to pair C
Short D - Cross-pair short to pair D
Cross A - Abnormal cross-pair coupling with pair A
Cross B - Abnormal cross-pair coupling with pair B
Cross C - Abnormal cross-pair coupling with pair C
Cross D - Abnormal cross-pair coupling with pair D