12
Specifications
Data bit length
Start bit, 1 bit + 8 bits + 2 stop bits + no parity
Baud rate
19200bps
Connector shape
USB (B type)
Format
18
OE
20
±
20
OF
OD
CAN
*
SO
Space
Code
Measurement Space
SI
Unit
CR
All data 21
CAN
:
Cancel
*
:
In memory mode = number of samples / in normal mode = space
SO
:
Specifies enlarged printout with double width.
±
:
+ tighten/- reverse
Measurement code
:
Includes a decimal point. If no decimal point, a space at the end.
1 0 . 0 0
10.00
SI
:
Releases the enlarged printout with double width.
Unit
:
In N•m or otherwise, the rest is a series of spaces.
N • m
N
•
m ( k g f
•
C m
kgf
•
cm )
CR
:
Carriage return
6-6. How to output data
Data is output every time the “CLEAR” key is pressed after measurement is completed. If the auto
reset is set, data is automatically output.
When you save the data using the memory function, the data is output with the procedure given below:
[1] Press the “MEM/OUTPUT” key, and the last saved memory number and measurement value
are displayed in turn.
[2] Press the “MEM/OUTPUT” key while the data number and measurement value are displayed.
[3] After “FA” (First Address) is displayed on the liquid crystal panel, the memory number is
displayed. Select the first memory number you want to output using the “UP” or “Down” key,
and then press the “MEM/OUTPUT” key.
[4] After “LA” (Last Address) is displayed on the liquid crystal panel, the memory number is
displayed. Select the last memory number you want to output using the “UP” or “Down” key,
and then press the “MEM/OUTPUT” key.
[5] “-P-“ is displayed on the liquid crystal panel, and the data is output. When output is finished,
the machine goes back to the measurement mode.
Note When you press the “CLEAR” key for 1 sec or more, the data output mode is cleared.
6-7. Changing data output speed
You can change the speed to output the saved data.
Note When you output the data in the high speed output setting, it might result in an error depending
on your PC and peripherals. If an error occurs, use the normal output mode.
• Normal output: [00] is displayed on the liquid crystal panel.
•
High speed output …[01] is
displayed on the liquid crystal panel.
* The default setting is [00].
• How to change the output speed
[1] Turn on the power by pressing the “ON/OFF” key as holding down the “PRG” key while the
power is OFF.
[2] When you let go the “PRG” key, “00” or “01” is displayed on the liquid crystal panel. Press the
“UP” key, and the speed setting is switched.
[3] After selecting the speed, press the “PRG” key, “-5-“ is displayed on the liquid crystal panel.
Then, the machine goes back to the torque display, and measurement becomes available.
Содержание delvo DLT1173A
Страница 2: ......