.Procedures of Installation to Robot/Tool
33
Robot side cables must be securely tied together with other cables and tubes
and fixed around the robot adaptor's connector part by using a spiral tube or
banding band, etc. Also ensure that cables and tubes are free of any excessive
force while the robot's wrist axis is rotating. Excessive force applied onto
cables and tubes may break a connector of the joint part and an electric
module, etc. or cause open-circuit. It may also cause any electric shock hazard
and sparking.
An example of cable fixing by a bracket is shown in lower illustration.
Fig. 16. Example of cable fixing
When a Servo Motor Module is used:
Perform wiring as per the delivery specification drawings. Improper wiring
may cause failure or electric leakage, etc.
Securely apply Class III grounding for earth and shield lines. Otherwise,
electric shock and noise may occur, leading any malfunctions.