background image

Note: This installation should be made by a 
qualified service person and conform with local 
codes. 

Specifications

 

VH3200

 System includes the following: 

 

(1) VH3200 Hub 

 

(1) Wall power transformer 

 

Size

 

 

 

1.75”H x 19”W x 10”D   

Input

   

 

Low voltage current loop from  

 

 

 

 

 

 

 

 

 

 

balanced UTP transmitters 

Power Requirements

 

24VAC, 

800mA 

   

Output-Video

   

1.0vpp composite video 

 

 

 

 

 

 

 

 

 

 

Monochrome or Color 

Model VH3200 

UTP Modular Hub 

Installation and 

Operation Manual 

Rev 021111 

NITEK

® 

Europe Office: 
De Schans 19-21 2a, 8231 KA Lelystad 
The Netherlands 
Tel: +31(0)320-230005  
Fax: +31(0)320-282186  
E-mail: [email protected] 
WWW.NITEK.NL 

USA Office: 
5410 Newport Drive, Rolling Meadows, IL  60008 
Phone: (800) 528-4343 
Fax: (847) 259-1300   
E-mail: [email protected] 
WWW.NITEK.NET 

680540101 

Reduce risk of fire or electrical shock. Do not 
expose this product to rain or moisture. 

Installation 

The 

VH3200

 UTP modular hub is designed to operate with a mix of Nitek UTP video cards either active or passive. 

If you are using pre-existing wire or are not sure of the distance you are going the following wire tests are highly 
recommended. 
 

Checking the Wire

 

1. 

Loop Resistance -

 Short one end and check the resistance between the wires at the other end. This will give 

you the loop resistance and wire distance (See Chart). 

2. 

Open Loop -

 Open the shorted end and check for infinity at the other end. 

3. 

Short or Leakage to Ground -

 With both ends open check each wire to earth ground. The reading should be 

infinity or megohms. 

4. 

No Voltage on Wires -

 With both wires open check for DC or AC, other than stray AC, on the wires. 

 
For distances greater than 3,000 feet an amplified transmit source may be needed. 

Wire 

Gage 

 500 

(150) 

1000 

(300) 

2000 

(600) 

3000 

(900) 

4000 

(1200) 

5000 

(1500) 

6000 

(1800) 

22 

16 32 64 97 129 

161 

194 

24 26  51  103 154 205 257 308 

26 41  82  163 245 326 408 490 

Distance in Feet  (Meters) 

Connecting the Hub 

If using the unit as a receiver, connect the twisted pair from the camera end to the screw terminals on the back, 
make sure of the polarity of the connection. If the wires are reversed the video will be unviewable on the monitor. 
Connect the matching BNC to your video system as needed. 
 
If using the unit as a transmitter, connect your video source to the BNC and connect the twisted pairs leading to 
your monitor end to the matching screw terminals. Note the polarity of your connections. 