Nitek IPPWR16 Скачать руководство пользователя страница 1

Model IPPWR16 

16 Port Gb PoE+ Surge Protector 

Installation and 

Operation Manual 

Rev 052912 

NITEK

® 

Europe Office: 
De Schans 19-21 2a, 8231 KA Lelystad 
The Netherlands 
Tel: +31(0)320-230005  
Fax: +31(0)320-282186  
E-mail: [email protected] 
WWW.NITEK.NL 

USA Office: 
5410 Newport Drive, Rolling Meadows, IL  60008 
Phone: (800) 529-8900 
Fax: (847) 259-1300   
E-mail: [email protected] 
WWW.NITEK.NET 

68-016-0103 

Specifications 

Enclosure Type 

  19” 

rack, 

2RU 

Height 

 

Connection Method

  

Standard 

RJ45 

    (16 

In 

16 

Out) 

 

Clamping Voltage

 

 

58v (on all lines) 

 

Network Type

 

  10/100/1000 

 

   PoE+ 

or 

non-PoE 

 

Temperature

 

  -40°C 

to 

+85°C 

Installation 

 

The IPPWR16 must be properly installed to insure maximum protection. The function of the IPPWR16 is to 

allow a surge to be routed to ground and to clamp the protected equipment video inputs to a minimum voltage. 
 

There are three key points to remember when installing the IPPWR16. First, provide a low impedance 

connection between the IPPWR16 and your protected equipment. This is best done by keeping the 

PROTECTED

  

Ethernet cable connections as short as possible, ideally less than 3 feet. 
 

Second, the system should use a single ground point. Connect the grounding stud of the IPPWR16 to a single 

ground point. A single ground point is a proper building ground to which equipment grounds are connected. Ideally, 
the protected equipment should be isolated from ground. If the IPPWR16 and the protected equipment are both 
grounded you will provide a parallel path to ground and a portion of the surge current can flow through that path. 
Additionally, AC power line protectors should be used to complete your surge protection strategy. 
 Finally, 

the 

UNPROTECTED

 cables and wires should not be crossed with the 

PROTECTED

 cables and wires. 

Crossing cables could provide a path for surge currents to bypass the IPPWR16 protection circuits. 

Description 

The 

IPPWR16 

is designed to provide 16 channels of 

surge protection for network devices. It can be used 
with both PoE+ and non-PoE devices.  The 
IPPWR16 is cost-effective and ideally suited for 
protecting multi-input devices such as a network 
hub, NVR, or groups of IP cameras or servers. The 
IPPWR16 is rack mountable in a standard 19” rack. 
It installs in minutes and provides a single easy 
access point for grounding. 

Network runs can be up 

to 100 meters

  

IPPWR16 

POE Switch 

Up to 15.4 watts

 

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: