NISSEI SWR/WATT METER Model TX-1202 User Manual

2019.1.21

English Version R1

PRODUCT MAIN FEATURE

This wattmeter series offer many innovative features typically not found at this price level
 • DC Grounded Antenna connector prevents electrostatic buildup.  
 • True Directional Coupler for increased accuracy over frequency.  
 • Low Bias Schottky Diode Detectors for increased linearity.  
 • Precision, large (104mm) Cross Needle Meter simultaneously displays
    forward and reflected power with SWR.  
 • Individual Meter Scales for each power range increase reading accuracy.  
 • LED backlighting provides smooth, even illumination.  
 • Three Color Scale for improved readability.  
 • DC Power Cable Included. 

SPECIFICATIONS

Model
Frequency Range
Center Calibrated

 28.5/145 MHz

435 MHz

1260 MHz

Power Range
Power Scale
Maximum Power
Accuracy 
Insertion loss 
Min. Power (Forward)
Testing Function
Input/Output Impedance
Input/Output Connectors
Input power
Dimension (W/H/D)
Weight (Net)

<FRONT PANEL>

<DESCRIPTION>

1. Indicator Display : Indicates FWD/REV power in watts
     and VSWR ratio
2. AVG/PEP (elliptical) push botton : Select AVG (out) or 
    PEP (depressed)
3. Frequency switch : Select frequency measured
4. Range switch : Selects RF power range multiplier 
    x1 x10 x100
5. LED ON/OFF button (elliptical) : Turn LED lamp
6. Zero adjust screws of analog cross needle meter

<REAR PANEL>

<DESCRIPTION>

7. TX connector : Coax connector to transmitter 50 ohm RF output
8. ANT connector : Coax connector to 50 ohm antenna system
9. 13.8V DC connection (via power supply) : LED illumination
    Note 1 : Watch out the LED wire must be correctly 
                 connected, black/white to '+', Black to '-'. 
                 Wrong connection burn LED)
     Note 2 : DC power is only required to run the meter 
                 backlight. This meter will function w/o DC power
                 in the AVG mode, even when switch off.

184 x 118 x 131 m/m

1100 g

50 ohm

"M" type for HF/VHF Band, "N" type for UHF Band

9-14 VDC 200 mA (Max.)

Less than 1.2 : 1 

1 W

Forward Power, Reversed Power, SWR, PEP

TX-1202

1.6 MHz - 1300 MHz

   0 - 200W

2/20/200W

200W

±

 10% of Full Scale or better

Отзывы: