Electrical and Control System
54
Service Manual – Floortec 760
Troubleshooting (Floortec 760 B)
Trouble
Possible causes
Remedy
The main motor does not start
The battery connector is disconnected
Connect
The batteries are discharged
Charge
The hopper is not in the correct position
Adjust
Check the operation of the microswitch
The upper hood is open
Close it properly
Check the operation of the microswitch
The circuit breaker (FA) is open
Press the push-button on the fuse, if the
trouble persists remove the overload cause
The right/left broom motor does not run
The lever is not activated correctly
Use the lever up to the end-of-stroke
Check the operation of the microswitch
The circuit breaker (FB) or (FC) is open
Press the push-button on the fuse, if the
trouble persists remove the overload cause