Dust Control System
32
Service Manual – Floortec 760
Troubleshooting
Trouble
Possible causes
Remedy
Dust/debris vacuuming is insufficient.
The filter is clogged.
Clean the dust filter by using the filter shaker
or by disassembling it.
The vacuum system compartment gasket is
damaged
Repair/replace
No vacuuming.
The electrical filter shaker does not work.
The hopper is full.
Empty the hopper.
The main motor circuit breaker (FA) is open.
Wait for the main motor to cool down, then
reset the fuse by pressing the relevant push-
button.
The fuse (F2) is open.
Replace the fuse.
The relay (K1) is broken.
Replace.
Dust/debris vacuuming is insufficient.
The switch (SW1) is not efficient.
Replace.
The filter shaker is broken.
Repair/replace.
The filter is clogged.
Clean the dust filter by using the filter shaker
or by disassembling it.
The vacuum system compartment gasket is
damaged
Repair/replace