![Nilfisk-ALTO 56114004 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/nilfisk-alto/56114004/56114004_service-manual_1693891061.webp)
Scrub System: Disc, Cylindrical, & Boost
61
Service Manual – Focus II / Scrubtec R6 Rider Autoscrubber
Deck Lift Actuator
1. For easier access to the actuator, you may wish to
2. For a better view of the upper retaining pin, you
described on page 37, or if so equipped, the
detergent system panel.
3. Disconnect the electrical power and position
switch connectors to the lift actuator.
4. Remove the upper pin
(2A)
from the lift actuator
by reaching in from below the machine while
looking through the opening behind the electrical
panel (or detergent cartridge)
(10)
.
•
If the actuator is going to be reinstalled
without modification, take care not to rotate
the spring housing relative to the motor/
leadscrew. If they remain unchanged, you can
reinstall the actuator without performing the
limit adjustment procedure.
5. Remove the lower pin
(2B)
and remove
the actuator.
6. If the same actuator is being replaced back
onto the machine, then perform the
page 58 before replacing the actuator.
7. If a new actuator is being installed, then
confirm the orientation of the springs and
nut described on the next page.
2A
10
2B