Electrical System 142
Service Manual – CS7000
Current Sensors
Amperage Measured
Voltage Output
120 A
4.5v
60 A
3.5v
45 A
3.25v
30 A
3.0v
15 A
2.75v
0 A
2.5v
-60 A
1.5v
-120 A
0.5v
Input/Output Table
Conn. Pin Wire
Desig.
Description
ID
Signal
Nominal Value
Black voltmeter lead
on:
J2
1
091 ORN/
YEL
Output
Left Front Turn Lamp LT7
12V OFF / 0V ON
B-(Ground)
J2
2
094 ORN/
BLU
Output
Left Rear Tail Lamp
LT9
12V OFF / 0V ON
B-(Ground)
J2
3
098 YEL/
RED
Output
Right Front Turn Lamp LT4
12V OFF / 0V ON
B-(Ground)
J2
4
101 YEL/
GRN
Output
Right Rear Stop/Turn
Lamp
LT11
12V OFF / 0V ON
B-(Ground)
J2
5
107 TAN/
BLK
Output
Tail Lamps
LT5 and
LT6
12V OFF / 0V ON
B-(Ground)
J2
6
064 BLK/
YEL
Output
Dust Control Motor
Contactor
K6
Grounds to
energize
36V OFF / 0V ON
B-(Ground)
J2
7
119 BRN/
WHT
Output
Detergent Pump
M17
PWM SIGNAL
(Reversing
Polarity)
0-12V
J2-19
J2
8
080 WHT/
GRN
Output
Squeegee Actuator
Motor
M12
Reversing
Polarity
Battery 30.5- 38V
Engine ON 37-40.5V
J2-9
J2
9
078 BLU/
BRN
Output
Squeegee Actuator
Motor
M12
Reversing
Polarity
Battery 30.5- 38V
Engine ON 37-40.5V
J2-8
J2
10 132 RED/
GRN
Output
Scrub Deck Actuator
Motor
M11
Reversing
Polarity
Battery 30.5- 38V
Engine ON 37-40.5V
J2-11
J2
11 135 YEL/
GRA
Output
Scrub Deck Actuator
Motor
M11
Reversing
Polarity
Battery 30.5- 38V
Engine ON 37-40.5V
J2-10
J2
12 162 BLK
Ground Supply
Battery Negative
Battery 30.5- 38V
Engine ON 37-40.5V
B+
J2
13 057 VIO
Power
Supply
VACC 1
Power supply
from Aux
Contactor
Battery 30.5- 38V
Engine ON 37-40.5V
B-(Ground)
J2
14 051 BLK/
ORN
Output
Auxiliary Contactor
K9
Grounds to
energize
36V OFF / 0V ON
B-(Ground)
J2
15 163 BRN/
BLK
Output
Side Broom Motor
Contactor
K8
Grounds to
energize
36V OFF / 0V ON
B-(Ground)
J2
16 063 GRN/
GRA
Output
Main Broom Motor
Contactor
K4
Grounds to
energize
36V OFF / 0V ON
B-(Ground)
J2
17 045 BLU Output
Vacuum Motor
Contactor
K5
Grounds to
energize
36V OFF / 0V ON
B-(Ground)
J2
18 150 BLK/
RED
Output
Shaker Motor
ground
M14
PWM SIGNAL
(half second
cycles)
Battery 30.5- 38V
Engine ON 37-40.5V
B-(Ground)
J2
19 116 WHT/
YEL
Output
Detergent Pump
M17
PWM SIGNAL
(Reversing
Polarity)
0-12V
J2-7
Содержание CS7000 Fuel Cell EcoFlex
Страница 110: ...Electrical System 110 Service Manual CS7000 Electrical Panel Contactor Relay location Electrical Panel ...
Страница 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Страница 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Страница 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Страница 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Страница 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Страница 154: ...Service Manual CS7000 154 Electrical System 56509170 Rev L Sheet 8 of 9 Before SN 1000048160 Kubota LPG before LEV E4 ...
Страница 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Страница 172: ...Engine System LPG 172 Service Manual CS7000 Low LP Pressure Switch Fuel Tank Pressure relief valve Fuel Tank Area ...
Страница 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...