INSTRUCTIONS FOR USE
ENGLISH
9100002290 - SC401
11
09/2017
USE/OPERATION
WARNING!
On some points of the machine there are some adhesive plates indicating:
–
DANGER
–
WARNING
–
CAUTION
–
CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates (see Visible Symbols On
The Machine paragraph).
Do not cover these plates for any reason and immediately replace them if damaged.
BATTERY CHECK/SETTING ON A NEW MACHINE
WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly installed
or connected.
The batteries must be installed by qualified personnel only. Set the battery charger according to the battery type
(WET or GEL/AGM).
Check the batteries for damage before installation.
Disconnect the battery connector and the battery charger plug.
Handle the batteries with great care.
Install the battery terminal protection caps supplied with the machine.
The machine requires two 12 V batteries, connected according to the diagram (28).
The machine can be supplied in one of the following modes:
Batteries already installed on the machine
1. Ensure that the battery connector (8) is connected.
2.
When first using the machine with new batteries, perform a full charging cycle (see the procedure in Maintenance chapter).
Without batteries
1. Buy appropriate batteries (see “Technical Data” paragraph).
2. Set the machine according to the type of batteries installed (WET or GEL) as shown in the following paragraph.
BATTERY INSTALLATION AND SETTING (WET
OR GEL)
Battery Installation
1. If equipped, remove the ignition key (41).
2. Disconnect the battery connector (8).
3. Lift the cover (34) and check that the recovery tank (33) is
empty; if not, empty it using the drain hose (12).
4. Close the cover (34).
5. Grasp the handle (16) and carefully lift the tank (33).
6. The machine is supplied with cables suitable to install
2 12 V batteries. Carefully lift the batteries up to the
compartment, then install them correctly.
7. Route and install the battery cables as shown in the
diagram in Figure 1, then tighten the nut on each battery
terminal.
8. Place the protection cap on each terminal, then connect
the battery connector (8).
9. Grasp the handle (16) and carefully lower the tank (33).
12 V
12 V
Figure 1
P100948
9100002290(A)09-2017.indb 11
24/10/2017 14:24:01