69
Service Manual – SW5500, FLOORTEC R 985
05 - Control System
Shop Measurements - Battery Powered Model
The following tables contain some “real world” shop voltage measurements to help you recognize what
“normal” looks like. All voltage values were measured with the black (Negative) voltmeter lead connected to
the main battery negative unless otherwise specified.
A battery powered machine was used for circuits that are common. Then engine powered machines were used for circuits
unique to the engine applications.
Shop Measurements - Main Machine Controller (EB1)
Battery Connection
B+
B-
Figure 39:
B-
B+
PIN
Color
Description
Measured/Condition
B+
Red
Main Machine Controller power
24.3V Sweeping System engaged
B-
Black
Main Machine Controller power supply -
0.28V Sweeping System engaged