263
Service Manual – SW5500, FLOORTEC R 985
51 - Dust Guard System
Water Nozzles and Filter Cleaning
1
Drive the machine on a level floor.
1 Turn the ignition key to “0”, then engage the parking brake
1 On the front side of the side brooms, remove the ring nuts (A) (bayonet connection)
1
Remove and clean the nozzles (B), the gaskets (C) and the filters (D) with compressed air. Remove any
calcium deposit. If necessary, replace the filters (D).
2
Reinstall the filters, gaskets and the nozzles, then fasten them with the ring nuts.
Figure 5:
A
C
A
B
D