69
34 - Scrub System, Disc
Removal and Installation
Scrub Skirt
Removing the scrub skirt
(B)
allows easy access to
the scrub deck components It is held in place with 4
screws
(A)
on the sides, and a tab in the center
1 Using a 3mm hex key, remove the 4 screws and
washers
(A)
2 Slide the skirt toward the front to free the center
tab from the solution tank
Scrub Brush Motor
1 Remove the Scrub skirt as described above
2 Remove the two halves of the brush housings
3 With the scrub deck fully raised, remove both
scrub brushes (even if only one motor is being
removed)
4 Using a 1/4” hex key, remove the socket head cap
screw
(A)
that secures the brush plate
(B)
to the
motor shaft
5 Slide the brush plate off the motor shaft
•
If you need to pry it off, try to pry evenly
•
Lubricant may help if it is corroded
•
Take care not to lose the motor shaft key
6 Using a 9/16” socket, remove the 4 screws that
secure the motor to the scrub deck
7 Slowly lower the scrub deck so the motor doesn’t
tip over (The deck can be lowered farther when
both brushes are removed )
8 Disconnect the motor connector, and remove the
motor from the scrub deck
A
B
A
B
C
D