4
Applications
90
Total Station NPL-322 Instruction Manual
Two-prism pole
1.
To enter the two-prism pole function, press
[3]
or
select
2Prism Pole
in the Offset menu.
2.
Sight the first prism and press
[MSR1]
or
[MSR2]
.
3.
Sight the second prism and press
[MSR1]
or
[MSR2]
.
4.
Enter the distance between the second prism and
the target point. Alternatively, if you do not need
QA information, you can leave the distance
between the first and the second prism blank.
5.
If you do enter a P1-P2 distance, the QA screen
appears. Compare the entered value and the
measured distance to check the accuracy of the
observation.
6.
To record the point, press
[ENT]
or the
OK
softkey.
Sample records
SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH
CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020
Note –
In this sample data, 0.5090 is the measured value. 0.5060 is the entered value.
Содержание NPL-322
Страница 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Страница 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Страница 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Страница 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Страница 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Страница 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Страница 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Страница 169: ...C H A P T E R 8 Total Station NPL 322 Instruction Manual 155 System Diagrams 8 In this chapter System Components ...
Страница 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Страница 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...