Total Station DTM-322 Instruction Manual
167
Error Messages
10
Recording Data
DATA FULL
100.19
The data storage is full.
Press any key to return to the Basic Measurement Screen (BMS). Then:
DUPLICATE PT
100.20
The input PT you are trying to record already exists in the current job. An existing
coordinate record cannot be overwritten by measured data.
Press any key to return to the point input screen. Change PT.
Duplicate PT
100.21
The input PT you are trying to record already exists in the current job as an SS, SO, or
CP record. An existing SS, SO, or CP record can be overwritten by measured data.
No Open Job
100.22
No job is open.
NO Stn Setup
100.23
There is no station record in the current job, or a station setup or BS check has not
been done since the program was rebooted.
To ...
Go to ...
delete unnecessary data
MENU > Data
delete jobs
MENU > Job
To ...
Press ...
return to the PT input screen
[ESC]
or the
Abrt
softkey
record RAW data and update XYZ data
the
XYZ
softkey
record RAW data only
the
RAW
softkey
To ...
Press ...
open the job list, if there are existing jobs
[1]
or select
Select job
create a new job
[2]
or select
Create job
return to the previous screen
[ESC]
To ...
Press ...
continue recording
[1]
or select
Continue
. If there is already an ST record in the
job, the message
CO, Use current orientation
appears.
go to the Stn Setup menu
[2]
or select
STN Setup
return to the previous screen
[ESC]
Содержание HQA46480
Страница 1: ...www trimble com Total Station DTM 322 Instruction Manual Version A 1 0 0 Part Number C232E April 2009 ...
Страница 8: ...viii Total Station DTM 322 Instruction Manual ...
Страница 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Страница 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Страница 157: ...C H A P T E R 8 Total Station DTM 322 Instruction Manual 143 System Diagrams 8 In this chapter System Components ...
Страница 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Страница 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...