Service Manual
HR15/17N HYBRID DC
English 07/16
26
3.3
Batteries
MAKE SURE SUITABLE EYE PROTECTION AND CLOTHING ARE WORN WHEN
MAINTAINING THE BATTERIES.
MAKE SURE THERE IS ADEQUATE VENTILATION WHEN CARRYING OUT
MAINTENANCE ON THE BATTERIES.
CONTACT WITH CONCENTRATED SULFURIC ACID RESULTS IN RAPID
DESTRUCTION OF BODY TISSUE VIA BURNS. IF INHALED, SEEK FRESH AIR AND
IMMEDIATE MEDICAL ATTENTION. IN THE EVENT OF SKIN OR EYE CONTACT,
FLUSH WITH LARGE VOLUMES OF WATER AND SEEK IMMEDIATE MEDICAL
ATTENTION. IN THE EVENT OF INGESTION, DO NOT INDUCE VOMITING AND
SEEK IMMEDIATE MEDICAL ATTENTION.
ABSORBENT GLASS MAT (AGM) BATTERIES ARE MAINTENANCE FREE AND DO
NOT REQUIRE TOPPING UP. IF IGNORED, IRREPARABLE DAMAGE TO THE
BATTERIES WILL OCCUR.
3.3.1
Condition Check (Daily)
1) Check that the batteries are fully charged. Batteries should be recharged at the end of each working
day or shift. See manufacturer's Operating Manual for correct battery charging procedure.
2) Check batteries for evidence of leaks or spilt battery acid. If material is released or spilled, lime or
soda ash may be used to neutralise, or flush with large volumes of water. Dispose of waste in
accordance with local regulations for acid and lead scrap. Use approved respiratory protection,
rubber gloves, and splash-proof safety goggles. Use rubber boots and acid-proof clothing for major
spills. Replace any defective batteries.
3) Check the condition of battery cables and link wires. Ensure that the insulation is intact along the
length of each cable. Replace any defective battery cables or link wires. Use insulated spanners on
battery terminals. Do not lay tools or other metal objects on the batteries.
4) Check that all battery cables and link wires are securely fastened to the battery terminals and
lubricated. Remove any corrosion from battery terminals and clamps. Ensure all surfaces are clean
and free of lubrication. Secure battery terminals using an insulated spanner. Once tightened and
secure, lubricate battery clamps with petroleum jelly to prevent corrosion.
3.3.2
Condition Check (Weekly) - Excludes AGM Batteries
1) Carry out all procedures listed above in Daily checks.
2) Remove all battery cell caps and check the fluid level in each cell in each battery. The level should
be sufficient to cover the plates. Top-up each battery cell as necessary
using distilled (deionised) water, do not overfill. Replace and tighten battery cell caps and put
batteries on charge. Leave batteries to stabilise for one hour before proceeding with further checks.