3.1.12 Bleeding Air From The Fuel System
DO NOT BLEED A HOT ENGINE. FUEL COULD SPILL ON TO THE EXHAUST
MANIFOLD CREATING A FIRE RISK.
MAKE SURE SUITABLE EYE PROTECTION AND CLOTHING ARE WORN WHEN
BLEEDING THE FUEL SYSTEM.
This procedure is required when;
•
the fuel filter and hoses have been detached and refitted
•
the fuel tank has become empty
•
the Niftylift has been in prolonged storage.
Fuel filter
1) Fill the fuel tank.
2) Open the fuel filter tap (1) as shown above.
3) Loosen air vent plug (2) by a few turns.
4) Tighten plug (2) once air bubbles are no longer
present in container (3).
5) Carry out procedure to bleed the fuel injection
pump before attempting to start the engine.
Fuel injection pump
1) Fill the fuel tank and bleed fuel filter.
2) Ensure air has been bled from the fuel filter.
3) Loosen air vent plug (1) on the fuel injection
pump.
4) Tighten plug once fuel flows and air bubbles
are no longer present.
5) Start the engine and inspect for leaks. If engine
fails to start repeat bleed procedure.
OFF/CLOSED
3
1
2