Service Manual
HR15/17N HYBRID DC
English 07/16
4
Replace all o-rings, seals and gaskets at reassembly.
Replace any parts with damaged threads; replace all roll pins, self locking fittings and circlips.
If any part resists removal check all fasteners, hydraulic lines, electrical wires and interferences before
continuing.
Keep all new parts in their packaging until they are to be installed, carry out inspection before installation.
Mark or tag all hydraulic lines before removal to avoid confusion and error. Never leave hydraulic lines
open or open them in a contaminated area. Always use plugs or caps.
Use only recommended lubricants. See section 2.4.2
.
In general, installation of components can be completed by reversing the removal process and
instructions.
Please refer to the following documents for further details.
For easy access to any of the above documents go to www.niftylift.com, register in the '
My Nifty
Registration
' section, then navigate to the '
My Nifty
' section and enter the
Niftylift Serial Number
.
1.4.3
Frequent Inspection
The owner of the Niftylift shall make sure that a frequent inspection is carried out in accordance
with the manufacturer’s instructions, on a Niftylift:
(1) That was purchased used. This inspection shall be accomplished unless it is determined that the
frequent and annual inspections are current.
(2) That has been in service for three months or 150 hours, whichever comes first.
(3) That has been out of service for a period longer than 3 months.
The inspection must be made by a person qualified as a technician on the specific type of Niftylift or one
having similar design characteristics. The inspection must be in accordance with items specified by the
manufacturer for a frequent Inspection and shall include, but not limited to the following:
(1) All functions and their controls for speed(s), smoothness, and limits of motion.
(2) Lower controls including the provisions for overriding of upper controls.
(3) All chain and cable mechanisms for adjustment and worn or damaged parts.
(4) All emergency and safety devices.
(5) Lubrication of all moving parts, inspection of filter element(s), hydraulic oil, engine oil, and coolant
as specified by the manufacturer.
Document
Number
HYBRID
DC ELECTRIC
Hydraulic Schematic
D81900
D81500
Electric Schematic
D81619
D81619
Operating and Safety Instructions
M50481
M50461
Parts Manual
M50480
M50460
Engine Operator’s Manual
M50291
-
Содержание HYBRID DC HR15N Series