background image

2. 

In the event of leakage of gas from the system, 

it is necessary to: - close 

the cylinder valve, - extinguish all sources of open fire, - do not use devices that 
may cause sparks (electric sockets, power switches, radios, TV sets, etc.), - open 
the  doors  and  windows  and  ventilate  the  room  thoroughly  (liquid  gas,  being 
heavier than air, accumulates in the lower parts of the room). In justified cases, 
notify your vendor - the gas supplier.

 

3.  In  the  event  of  a  fire  in  the  room  or  cylinder

,  if  possible, turn  off  the 

valve and remove it from the room into the open air. If this is not possible, cool the 
cylinder  as  much  as  possible  using  a  stream  of  water  or  heavy  wet  rags.  The 
presence of gas cylinders in the room on fire should be reported to the supervisor 
of the firefighting brigade.

 

 

NOTE!: 

1.  It is forbidden to check the system for leaks using a flame. 
2.  It is not allowed to cover air vents. 
3.  It  is  necessary  to  regularly  check  the  condition  of  gas  hoses  and, 

when the need arises but always before the expiration date indicated 
on the hoses, replace them with new ones, exclusively approved for 
use in gas systems. 

4.  One approved dry powder or ISO 7165 compliant fire extinguisher, 

with a capacity of at least 1 kg, and a fire blanket should be located 
near  kitchen  appliances,  in  the  vicinity  of  the  front  door.  It  is 
necessary  to  familiarise  yourself  with  the  fire  extinguisher  manual 
and  the  local  fire  protection  regulations.  Fire  extinguisher  and 
blanket not included 

5.  Never  allow  unqualified  persons  to  modify  LPG  systems  or 

equipment. 

 

NOTE ! 

 

Improper handling can result in significant amounts of gas 

escaping or poor combustion, which can cause a fire or poisoning. 
Carbon monoxide exhaust poisoning manifests as tinnitus, 
heaviness, increased heart rate, dizziness, vomiting and general 
weakness. The person affected should be given first aid and an 
ambulance should be called. When giving first aid, you should: 

 
 
 
 
 
 
 
 

-17- 

- take the person affected out into fresh air 

- facilitate breathing by unzipping their clothing, 
- administer sobering agents for inhalation (e.g. ammonia), 
- cover the patient with a blanket and do not let them fall asleep 
-  call for medical help and constantly supervise the patient until 

medical help arrives 

 

6.5.4. PLUMBING SYSTEM 

 

The plumbing system includes: 

- water supply lines 
- water tank, capacity 30 l 
- water drain line 
- electric valve tap 
- electric pump 

 

The water tank is located in the left front sofa. 
Place the pump in the water tank. Water flows out of the tap when the valve is 

turned (the pump is turned on automatically). 

The water used is discharged through a system of water lines under the 

caravan. 

It is recommended to park the caravan in a caravan site over a drainage grate 

so that the water flowing out does not spill over the sides. 

 

6.5.5. TRAVEL TOILET 

 

The caravan is equipped with a travel toilet. The toilet is fitted with a tank, 

accessed from the outside of the caravan through a special door. 

 

For a detailed description of the use and operation of the travel toilet, 

please refer to the manual supplied with the caravan. 

 

7. BODYWORK MAINTENANCE 

 

Caravan body and windows 

Bodywork maintenance consists in keeping it clean. The laminate can be 

secured  against  dirt  absorption  using  wax  preparations  designed  for  car 
bodyworks  and  wet  cleaned,  preferably  with  special  washing  agents.  Windows 
should be washed using a soft cloth, thoroughly rinsed with water and protected 
against scratches. 

 
 
 
 
 

 

-18- 

 

Содержание Caravan N-Cross

Страница 1: ...BEFORE DRIVING 7 4 4 DRIVING 8 4 5 UNHITCHING 8 5 OPERATION SERVICE CHASSIS MAINTENANCE 8 5 1 GENERAL INFORMATION 8 5 2 BALL COUPLING 9 5 3 SUSPENSION 9 5 4 WHEELS 10 5 5 BRAKING SYSTEM 10 5 6 JOCKEY...

Страница 2: ...satisfied with our product we wish you a safe journey 1 TECHNICAL DATA Length 5610 mm Total width 2170 mm Total height 2400 mm Bodywork length 3750 mm Interior bodywork width 2 050 mm Interior bodywor...

Страница 3: ...c 11 Travel toilet 1 pc 12 230V connection cable with a length of 25 lin m 1 pc 13 Electric water pump 1 pc 14 Caravan instruction manual 1 pc 15 Gas stove manual 1 pc 16 Cooler manual 1 pc 17 Indoor...

Страница 4: ...tallation for battery charging 21 Refrigerator DOMETIC RM4210 12V 230V gas 80l 4 CARAVAN OPERATION 4 1 HITCHING 5 Fig 2 Day layout a and night layout b of the N Cross DS caravan 1 gas stove 2 sink 3 f...

Страница 5: ...st movement 4 Put the tables in the sleeping position 5 Turn off all gas appliances 6 Check the tightness of the fixing screws securing wheels 7 Disconnect the jockey wheel or pull it upwards as far a...

Страница 6: ...ossible to purchase such a lock as a piece of additional equipment 5 3 SUSPENSION All caravans manufactured by NIEWIAD W Sp z o o are fitted with axles with rubber spring elements The suspension syste...

Страница 7: ...gas cylinder valve and the corresponding valve applicable when the trailer is equipped with more than one gas consuming appliance in the kitchen cabinet light the lighter and bring it close to the bur...

Страница 8: ...hooks fold the table leg 4 by pushing the button 3 remove the table from the aluminium slat 2 and place it on the slat 6 while laying the table on the bed edges 5 1 7 13 6 5 INTERNAL SYSTEMS 6 5 1 12V...

Страница 9: ...nd tearing it off 3 The reducer connection on the valve has a left hand thread Use a 27mm wrench to loosen the plastic cap and turn it right clockwise Tighten the reducer cap by turning it countercloc...

Страница 10: ...or poor combustion which can cause a fire or poisoning Carbon monoxide exhaust poisoning manifests as tinnitus heaviness increased heart rate dizziness vomiting and general weakness The person affect...

Страница 11: ...workshop Date Type of activity after 2 000 km or no later than after 6 months Wheel bearing inspection Lubrication of the bearing sleeves of the overrun device after every 10 000 km or every 12 month...

Отзывы: