Страница 1: ...USER MANUAL EC1210 DIGITAL EC METER FOR SOIL ...
Страница 2: ...3 CE Marking 4 2 4 Safety warnings 4 3 INSTRUCTION MANUAL CONTENTS 5 3 1 Manual revision 5 3 2 Symbols 5 3 3 How to read the instruction manual 6 3 3 1 Using the instrument on the field 6 3 3 2 Plant maintenance staff 6 4 SPECIFICATIONS 7 4 1 Functional specification 7 4 2 Technical specifications 8 5 OPERATING PROCEDURES 11 5 1 Operating instructions 11 5 1 1 Main measuring 11 5 1 2 EC calibratio...
Страница 3: ...mperature sensor is connected it will display the temperature values 3 it performs an automatic or manual temperature compensation for EC measures 4 it performs the manual or automatic EC calibration 5 it allows the memorization and the visualization up to 80 readings 1 2 FUNCTIONAL PRINCIPLES The conductivity meter is used to detect the electric conductivity of liquids and to control the salt con...
Страница 4: ...charge Technical Assistance over the phone for problems regarding installation calibration and regular maintenance a Repairing Service in our Aalsmeer Holland headquarter for all types of damages calibration or for a scheduled maintenance Please take a look at the Technical Support data sheet at the end of the manual for more details 2 3 CE MARKING This instrument is manufactured according to the ...
Страница 5: ...leased versions of the same manual so to help users that are already familiar with the product Rev A First release 3 2 SYMBOLS Throughout the manual You may find the following symbols which are both dictated by a Norm or that are simply conventional Symbol Meaning Attention pay great attention to what written next to this symbol This symbol is used to warn users that if the instructions are WARNIN...
Страница 6: ...become more familiar with the product by describing its accessories and its use The user can then verify if he she has the necessary know how to use the meter Note Maintenance staff could be more interesting in the chapters regarding users instructions calibration maintenance 3 3 1 Using the instrument on the field The end user can operate the meter by reading the EC temperature and eventually rec...
Страница 7: ...erature PT1000 sensor the meter also provide the temperature readout Scales The meter can provide the conductivity measuring in µS or mS and the temperature in C or F Calibration During the EC calibration the meter recognize automatically the memorized standard solutions Power supply The meter is operated by a 9 VDC battery Instrument setup The meter has the set up menu to select the measuring sca...
Страница 8: ...no EC5015 EC range Resolution under value max range 20 00 µS 0 01 µS 1 00 µS 21 00 µS 200 0 µS 0 1 µS 10 0 µS 210 00 µS 2000 µS 1 µS 100 µS 2100 µS 20 00 mS 0 01 mS 1 00 mS 21 00 mS 200 0 mS 0 1 mS 10 0 mS 210 0 mS Under range uS mS Above range uS mS Zero 10 0 1 1 Calibration of zero is performed for each range starting from the lower one Sens 60 160 100 1 2 Calibration manual automatic with KCL s...
Страница 9: ...RAMETERS Model en revision FW EC1210 Rev 1 0 01 11 S1 0 EC range 20 200 2000 µS 20 200 mS 20 mS Reaction time 90 0 10 sec 2 s S5 0 Temp unit C F C S6 0 Reference temp 20 25 C 25 C S7 0 Temp coëfficiënt 0 00 3 50 C 2 20 C S8 0 Auto shut off button 30 600 sec 90 sec S9 0 4 0 DATALOGGER Memory type non volatile EEPROM 100k write Memory capacity 80 measurements Memory numbers 0 79 Memory format REC n ...
Страница 10: ...FF Instrument switch OFF for action 3 seconds 2 LOG INCR Z CAL LOG Memo record when in measure INCR Increase value Scrolling vertical menu Z CAL Zero cal for action 3 s when in measure 3 SET UP SHIFT S CAL ENTER SET UP Access to Set up menu when in measure SHIFT Cursor shift Horizontal menu S CAL Sensitivity calibration for action 3 s when in measure ENTER Enter for action 3 s when in CAL or SET U...
Страница 11: ...suring Press one time the key MODE The meter will go to the D2 0 or D3 display and it will show the temperature value of the sample in C or F according to the set up selection The automatic manual temperature compensation is available for the EC measuring Data logging During the EC press the key LOG to memorize the EC value the temperature value the reference temperature value the temperature coef...
Страница 12: ...is out of the accepted limits the display will show the error message Zero err ENTER push the key for 3 seconds to delete the message and to turn to main display If the new value is accepted the display will show the message Last cal for few seconds and then it proposes to insert the date by the flashing cursor under last digit XX XX XX INCR push the key to modify the last digit if necessary SHIFT...
Страница 13: ...ed standard solution value doesn t correspond to the buffer solution used for the calibration proceed as follow SHIFT push the key to read the memorized standard solution value with the flashing cursor under the digit XX XX mS or µS INCR push the key to modify the last digit if necessary SHIFT push the key to position the cursor on the other digit to be modified with same procedure ENTER push the ...
Страница 14: ...T push the key to read the manual temperature value with the flashing cursor on the last digit XXX X CM or FM INCR push the key to modify the last digit if necessary SHIFT push the key to position the cursor on the other digit to be modified with same procedure ENTER push the key for 3 seconds to confirm the adjusted value At this point the procedure is same as the above steps The message Update i...
Страница 15: ...y SHIFT push the key to read the number of the record the alternate values of the EC and temperature LOG SHIFT press the two keys for 3 seconds The message Logged erased will appear MODE push the key to turn to the main display To verify if records are erased MODE push the key to reach the display View Log SHIFT push the key to read the message Empty 5 1 4 Set up This function allow the user to se...
Страница 16: ...ure measuring unit The meter is delivered with the C temperature measuring unit and it can be modified to F by means of the following procedure Follow the same procedure to turn back to C unit SHIFT push the key from the main display The message Set up will appear SHIFT push the key The p n and the firmware release will appear EC1210 and Rev 1 xx INCR push the key three times The messages T Unit C...
Страница 17: ...ds The display will show the p n and the firmware release EC1210 and Rev 1 xx MODE push the key two times to turn to the main display 5 1 5 Maintenance of the unit Quality components are used to give the meter a high reliability In this way it needs just the battery replacement Battery replacement The meter controls the voltage of the battery If the value is lower than 7 5 volt the display will sh...